Delayed gadolinium-enhanced MRI of cartilage is a technique for studying the development of osteoarthritis using quantitative T(1) measurements. Three-dimensional variable flip angle is a promising method for performing such measurements rapidly, by using two successive spoiled gradient echo sequences with different excitation pulse flip angles. However, the three-dimensional variable flip angle method is very sensitive to inhomogeneities in the transmitted B(1) field in vivo. ⋯ Phantom studies concluded that three-dimensional variable flip angle with B(1) correction calculates accurate T(1) values also in areas with high B(1) deviation. Retrospective analysis of in vivo hip delayed gadolinium-enhanced MRI of cartilage data from 40 subjects showed the difference between three-dimensional variable flip angle with and without B(1) correction to be generally two to three times higher at 3 T than at 1.5 T. In conclusion, the B(1) variations should always be taken into account, both at 1.5 T and at 3 T.
-
The application of compressed sensing is demonstrated in a recently implemented four-dimensional echo-planar based J-resolved spectroscopic imaging sequence combining two spatial and two spectral dimensions. The echo-planar readout simultaneously acquires one spectral and one spatial dimension. ⋯ The four-dimensional echo-planar-based J-resolved spectroscopic imaging data acquired in a prostate phantom containing metabolites at physiological concentrations are accurately reconstructed with as little as 20% of the original data. Experimental data acquired in six healthy prostates using the external body matrix "receive" coil on a 3T magnetic resonance imaging scanner are reconstructed with acquisitions using only 25% of the Nyquist-Shannon required amount of data, indicating the potential for a 4-fold acceleration factor in vivo, bringing the required scan time for multidimensional magnetic resonance spectroscopic imaging within clinical feasibility.
-
Off-resonance artifacts hinder the wider applicability of echo-planar imaging and non-Cartesian MRI methods such as radial and spiral. In this work, a general and rapid method is proposed for off-resonance artifacts correction based on data convolution in k-space. The acquired k-space is divided into multiple segments based on their acquisition times. ⋯ The technique was demonstrated in phantom and in vivo studies for radial, spiral and echo-planar imaging datasets. For radial acquisitions, the proposed method allows the self-calibration of the field map from the imaging data, when an alternating view-angle ordering scheme is used. An additional advantage for off-resonance artifacts correction based on data convolution in k-space is the reusability of convolution kernels to images acquired with the same sequence but different contrasts.
-
Chemical exchange saturation transfer (CEST) is a technique to indirectly detect pools of exchangeable protons through the water signal. To increase its applicability to human studies, it is needed to develop sensitive pulse sequences for rapidly acquiring whole-organ images while adhering to stringent amplifier duty cycle limitations and specific absorption rate restrictions. In addition, the interfering effects of direct water saturation and conventional magnetization transfer contrast complicate CEST quantification and need to be reduced as much as possible. ⋯ Fortunately, the limited width of the direct water saturation signal could be exploited to fit it with a Lorentzian function allowing CEST quantification. Amide proton transfer effects ranged between 1.5% and 2.5% in selected white and grey matter regions. This power and time-efficient 3D pulsed CEST acquisition scheme should aid endogenous CEST quantification at both high and low fields.
-
An alternative to the standard echo-planar spectroscopic imaging technique is presented, spectroscopic imaging using concentrically circular echo-planar trajectories (SI-CONCEPT). In contrast to the conventional chemical shift imaging data, the sampled data from each set of concentric rings were regridded into Cartesian space. Usage of concentric k-space trajectories has the advantage of requiring significantly reduced slew rates than echo-planar spectroscopic imaging, allowing for the collection of higher spectral bandwidths and opening the door for high-bandwidth echo-planar styled spectroscopic imaging at higher magnetic fields. ⋯ The feasibility of using concentric k-space trajectories is demonstrated, and the spatial profiles and representative spectra are compared with the standard echo-planar spectroscopic imaging technique in a gray matter phantom containing metabolites at physiological concentrations and healthy human brain in vivo. The symmetric nature of the concentric circles also reduces the number of required excitations for a given resolution by a factor of two. Possible artifacts and limitations are discussed.