Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine
-
To develop a Fourier-transform based velocity-selective inversion (FT-VSI) pulse train for velocity-selective arterial spin labeling (VSASL). ⋯ A novel FT-VSI pulse train was demonstrated to be a suitable labeling module for VSASL with robustness of velocity-selective profile to B0/B1 field inhomogeneity and gradient imperfections. Compared with conventional VSASL, FT-VSI prepared VSASL produced consistent CBF maps with higher SNR values. Magn Reson Med 76:1136-1148, 2016. © 2015 Wiley Periodicals, Inc.
-
Comparative Study
Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T.
To determine the test-retest reproducibility of neurochemical concentrations obtained with a highly optimized, short-echo, single-voxel proton MR spectroscopy (MRS) pulse sequence at 3T and 7T using state-of-the-art hardware. ⋯ State-of-the-art MRS methodology allows excellent reproducibility for many metabolites with 5-min data averaging on clinical 3T hardware. Sensitivity and resolution advantages at 7T are important for weakly represented metabolites, short acquisitions, and small volumes of interest. Magn Reson Med 76:1083-1091, 2016. © 2015 Wiley Periodicals, Inc.
-
Dynamic contrast enhanced (DCE) imaging is a widely used technique in oncologic imaging. An essential prerequisite for obtaining quantitative values from DCE-MRI is the determination of the arterial input function (AIF). However, it is very challenging to accurately estimate the AIF using MR. A comprehensive model, which uses complex data instead of either magnitude or phase, was developed to improve AIF estimation. ⋯ By using the complex signal, the AIF estimation becomes more accurate and precise. This might enable patient specific AIFs, thereby improving the quantitative values obtained from DCE-MRI. Magn Reson Med 76:1236-1245, 2016. © 2015 Wiley Periodicals, Inc.
-
To develop a free-breathing variable flip angle (VFA) balanced steady-state free precession (bSSFP) cardiac cine imaging technique with reduced specific absorption rate (SAR) at 3 Tesla. ⋯ FB-VFA bSSFP cardiac cine imaging decreased the SAR at 3T with image quality sufficient to perform cardiac functional analysis. Magn Reson Med 76:1210-1216, 2016. © 2015 Wiley Periodicals, Inc.
-
The design of RF coils for MRI transmit becomes increasingly challenging at high frequencies required for MRI at 7T and above. Our goal is to show a proof of principle of a new type of transmit coil for higher field strengths. ⋯ By choosing the dielectric and the dimensions adequately, the dielectric waveguide couples the magnetic field efficiently into the body. The waveguide can be redesigned for higher frequencies by simple adaptations and may be a promising transmit alternative. Magn Reson Med 76:1314-1324, 2016. © 2015 Wiley Periodicals, Inc.