Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine
-
In three-dimensional (3D) coronary magnetic resonance angiography (MRA), the in-flow contrast between the coronary blood and the surrounding myocardium is attenuated as compared to thin-slab two-dimensional (2D) techniques. The application of a gadolinium (Gd)-based intravascular contrast agent may provide an additional source of signal and contrast by reducing T(1blood) and supporting the visualization of more distal or branching segments of the coronary arterial tree. In six healthy adults, the left coronary artery (LCA) system was imaged pre- and postcontrast with a 0.075-mmol/kg bodyweight dose of the intravascular contrast agent B-22956. ⋯ For comparison, state-of-the-art baseline 3D coronary MRA with T(2) preparation for non-exogenous contrast enhancement was acquired. The combination of IR 3D coronary MRA, sophisticated navigator technology, and B-22956 allowed for an extensive visualization of the LCA system. Postcontrast, a significant increase in both the signal-to-noise ratio (SNR; 46%, P < 0.05) and contrast-to-noise ratio (CNR; 160%, P < 0.01) was observed, while vessel sharpness of the left anterior descending (LAD) artery and the left coronary circumflex (LCX) were improved by 20% (P < 0.05) and 18% (P < 0.05), respectively.
-
The efficiency of MRI-guided focused ultrasound (FUS) hyperthermia with continuous sonication was investigated for the treatment of VX2 carcinoma implanted in rabbit thigh muscle. Six rabbits were treated with a single session of FUS when the tumor diameter exceeded 2 cm (10-21 days after implant). The FUS treatment method was based on a spiral trajectory of the focal point that allows continuous sonication under automatic, real-time MR guidance. ⋯ Thermal injury was limited to the targeted region in three cases, but ablation also reached some healthy muscle around the tumor in the other three cases. A good correlation was found between postmortem histological analysis and premortem MRI data. Efficacy of MR-controlled hyperthermia using FUS heating with spiral trajectories was demonstrated for successful local control of intramuscular VX2 tumor.
-
Comparative Study Clinical Trial
Reproducibility of localized 2D correlated MR spectroscopy.
The test-retest reliability of two-dimensional (2D) correlated spectroscopy (COSY) was studied on a whole-body 1.5T MRI scanner. Single-voxel localized 2D proton spectra were recorded in vitro as well as in vivo using a recently implemented localized chemical shift correlated spectroscopic (L-COSY) sequence. ⋯ The 2D metabolite ratios and the raw volume integrals of 2D diagonal and cross peaks in healthy human brain were very well reproduced. The intraclass correlation coefficients were greater than 0.4 (P < 0.05) for the major metabolites, indicating that the 2D peak volumes were stable enough within individuals to detect reliable differences between normal subjects.
-
Comparative Study
FIESTA-ET: high-resolution cardiac imaging using echo-planar steady-state free precession.
This work describes a technique that combines multishot echo-planar imaging (EPI) with steady-state free precession (SSFP, also known as TrueFISP, FIESTA, and balanced FFE) for multislice, cine MR imaging of the heart. Unlike recently reported methods, the technique presented here (FIESTA-ET) is high-resolution and does not require offline reconstruction or postprocessing. It is therefore suitable for use on standard clinical scanners. ⋯ While providing comparable image quality, FIESTA-ET required half the acquisition time per slice of conventional FIESTA. Because multiple slices could be imaged in a single breathhold, the entire heart could be scanned in less than 2 min. Although the FIESTA-ET images exhibited an unexpected increase (P < 0.0005) in myocardial SNR of 16% over FIESTA, the volumetric measurements showed excellent correlation.
-
The benefits of sensitivity-encoded (SENSE) echo-planar imaging (EPI) for functional MRI (fMRI) based on blood oxygen level-dependent (BOLD) contrast were quantitatively investigated at 1.5 T. For experiments with 3.4 x 3.4 x 4.0 mm(3) resolution, SENSE allowed the single-shot EPI image acquisition duration to be shortened from 24.1 to 12.4 ms, resulting in a reduced sensitivity to geometric distortions and T(*)(2) blurring. Finger-tapping fMRI experiments, performed on eight normal volunteers, showed an overall 18% loss in t-score in the activated area, which was substantially smaller than expected based on the image signal-to-noise ratio (SNR) and g-factor, but similar to the loss predicted by a model that takes physiologic noise into account.