Randomized Controlled TrialBispectral index as a predictor of sedation depth during isoflurane or midazolam sedation in ICU patients.
Bispectral index (BIS) is used for monitoring anaesthetic depth with inhaled anaesthetic agents in the operating room but has not been evaluated as a monitor of sedation depth in the intensive care unit (ICU) setting with these agents. If BIS could predict sedation depth in ICU patients, patient disturbances could be reduced and oversedation avoided. Twenty ventilator-dependent ICU patients aged 27 to 80 years were randomised to sedation with isoflurane via the AnaConDa or intravenous midazolam. ⋯ In conclusion, BIS XP does not reliably predict sedation depth as measured by clinical evaluation in non-paralysed ICU patients sedated with isoflurane or midazolam. EMG contributes significantly to BIS values in isoflurane or midazolam sedated, non-paralysed ICU patients. End-tidal isoflurane concentration appeared to be a better indicator of clinical sedation depth than BIS.
-
Anaesth Intensive Care · Jun 2007
Randomized Controlled TrialImpact of bispectral index monitoring on propofol administration in patients undergoing cardiopulmonary bypass.
Propofol anaesthesia using target control infusion during cardiac surgery has become more popular recently. However, without depth of anaesthesia monitoring, the standard target concentration used may be higher than necessary to maintain adequate hypnosis during hypothermic cardiopulmonary bypass. The purpose of this study was to evaluate the effect of bispectral index monitoring on propofol administration during hypothermic cardiopulmonary bypass. ⋯ The bispectral index value during bypass was significantly lower in group C than in group B, reflecting a deeper state of anaesthesia. There was no difference in the use of inotropes, vasoconstrictors or vasodilators. Bispectral index monitoring enables a 50% reduction in propofol administration at this standard dose during hypothermic cardiopulmonary bypass.
-
Anaesth Intensive Care · Jun 2007
Randomized Controlled TrialClosed-loop anaesthesia delivery system (CLADS) using bispectral index: a performance assessment study.
The development of electroencephalographic indices of anaesthetic depth has in turn generated interest in automated anaesthesia delivery systems using these as the input variable. In this paper, one patented closed loop anaesthesia delivery system (CLADS) (502/DEL/2003) is compared to manual control of propofol delivery titrated to the bispectral index (BIS). Forty ASA I-II patients undergoing elective surgery under general anaesthesia were enrolled in the study. ⋯ Smaller amounts of anaesthetic agent were required (P < 0.01) and there was faster postoperative recovery (P < 0.05). Manual delivery of propofol required the infusion rate to be changed a median of 30 times (IQR 12-45), which required considerable time and attention by the anaesthetist. In conclusion, automated delivery of propofol adjusted to the bispectral index using our CLADS was both effective and efficient as compared to manual control.