Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery
-
Otolaryngol Head Neck Surg · Jun 1999
Comparative StudyHearing screening in the newborn intensive care nursery: comparison of methods.
Patients in the neonatal intensive care unit were tested by hearing screening tests including auditory brain stem response (ABR), transient and distortion-product otoacoustic emissions (TEOAEs and DPOAEs), and acoustic stapedius reflex (ASR), and by middle ear function tests including multifrequency tympanometry and pneumatic otoscopy. Pass rates on hearing tests were 75% to 89%. TEOAEs produced the lowest pass rate, and DPOAEs the highest. ⋯ Of patients who failed 226-Hz and 678-Hz tympanometry, 30% to 67% passed hearing tests, suggesting a high false-positive rate for these immittance tests. The 3 ears that failed the 1000-Hz tympanogram failed all hearing tests. Many ears were abnormal by pneumatic otoscopy but passed hearing tests, suggesting that the usual ear examination criteria may not apply to infants.