EMERGE: Evaluating the value of Measuring Random Plasma Glucose Values for Managing Hyperglycemia in the Inpatient Setting.
A diagnosis of diabetes is considered when a patient has hyperglycemia with a random plasma glucose ≥200 mg/dL. However, in the inpatient setting, hyperglycemia is frequently non-specific, especially among patients who are acutely unwell. As a result, patients with transient hyperglycemia may be incorrectly labeled as having diabetes, leading to unnecessary treatment, and potential harm. ⋯ Hyperglycemia in hospital is common but does not necessarily indicate a patient has diabetes. Furthermore, it can lead to treatment with diabetes medications with potential harm. Our findings highlight that clinicians should be cautious when responding to elevated random plasma glucose tests in the inpatient setting.