The Laryngoscope
-
Ninety-one laser laryngeal procedures using the apneic technique of anesthesia were performed in 28 patients between 2 months and 64 years of age. Seventy-two procedures (79%) were performed on children and 19 on adults. There were no complications. ⋯ The apneic technique described in this paper provides a laser operative field free of an endotracheal tube, virtually eliminating the danger of a laser fire. It is a relatively safe and effective means of performing laser laryngeal surgery. In addition, the Laser-Flex endotracheal tube appears to be an acceptable alternative to a metallic tape-wrapped endotracheal tube.