Clinical biomechanics
-
Clinical biomechanics · Mar 2017
Comparative StudyIs pelvic fixation the only option to provide additional stability to the sacral anchorage in long lumbar instrumentation? A comparative biomechanical study of new techniques.
Supplementary iliac screws have the highest potential to protect S1-pedicle-screws from loosening in long fusion constructs. However, this technique bridges the iliosacral joint with potential disadvantages for the patient. This study aimed to evaluate if two different established fixation techniques can be used in addition to pedicle screws as alternative to iliac screws, and if these two techniques can provide similar stability when S1-pedicle-screws are loosened. ⋯ In long lumbar pedicle screw instrumentations including L5/S1, additional ilium screws have the highest potential to protect the S1-anchorage. Additional L5/S1-translaminar-screws can increase stability of the lumbosacral junction without bridging the iliosacral joint, whereas lamina hooks showed no significant biomechanical benefit.