Canadian journal of anaesthesia = Journal canadien d'anesthésie
-
Review Meta Analysis Comparative Study
Efficacy of palonosetron for preventing postoperative nausea and vomiting: a systematic review and meta-analysis.
Palonosetron, a second-generation 5-hydroxytryptamine 3 receptor antagonist (5-HT3RA), has unique characteristics relative to first-generation 5-HT3RAs such as ondansetron. Nevertheless, it remains unclear if palonosetron is better than ondansetron for the prevention of nausea and vomiting during the first 24 hr after surgery and is thus the focus of this systematic review. ⋯ Palonosetron provides more effective prophylaxis of early PON, late PON, and late POV compared with ondansetron. Future studies are required to investigate the role of palonosetron during 24-72 hr following surgery.
-
Review Meta Analysis Comparative Study
Efficacy of palonosetron for preventing postoperative nausea and vomiting: a systematic review and meta-analysis.
Palonosetron, a second-generation 5-hydroxytryptamine 3 receptor antagonist (5-HT3RA), has unique characteristics relative to first-generation 5-HT3RAs such as ondansetron. Nevertheless, it remains unclear if palonosetron is better than ondansetron for the prevention of nausea and vomiting during the first 24 hr after surgery and is thus the focus of this systematic review. ⋯ Palonosetron provides more effective prophylaxis of early PON, late PON, and late POV compared with ondansetron. Future studies are required to investigate the role of palonosetron during 24-72 hr following surgery.
-
Photoplethysmography permits continuous measurement of heart rate and peripheral oxygen saturation and has been widely used to inform clinical decisions. Recently, a myriad of noninvasive hemodynamic monitoring devices using this same technology have been increasingly available. This narrative review aims to summarize the principles that form the basis for the function of these devices as well as to comment on trials evaluating their accuracy and clinical application. ⋯ Although respiratory variations of the plethysmographic waveform correlate only modestly with the arterial blood pressure waveform, fluid responsiveness can be relatively consistently assessed using both approaches. Continuous blood pressure measurements obtained using the volume-clamp technique may be as accurate as conventional brachial noninvasive blood pressure measurements. Most importantly, clinical comparative effectiveness studies are still needed in order to determine if these technologies can be translated into improvement of relevant patient outcomes.