The Journal of arthroplasty
-
A large Q angle induced by technical error such as an internally rotated femoral component causes patellar failure after total knee arthroplasty. The effect of medial displacement of the tibial tubercle to decrease the Q angle for patellar tracking was studied by evaluating the patellar position relative to the patellar groove on the femoral component in cadaver specimens. A 5 degrees internally rotated femoral component caused the patella to shift medially about 5 mm, and also caused the tibia to rotate internally about 3 degrees at full extension. ⋯ Medialization of the tibial tubercle caused the patella to shift about 2 mm medially from the patellar groove. The transfer also caused an external rotation of the tibia (2 degrees-5 degrees). Medial transfer of the tibial tubercle changes patellar kinematics and corrects the tendency toward lateral patellar dislocation caused by internally rotating the femoral component; however, it also creates minor patellar and tibial kinematic changes that may have a clinical effect.