Rapid communications in mass spectrometry : RCM
-
Rapid Commun. Mass Spectrom. · Jan 2001
Use of matrix-assisted laser desorption/ionization time-of-flight mass mapping and nanospray liquid chromatography/electrospray ionization tandem mass spectrometry sequence tag analysis for high sensitivity identification of yeast proteins separated by two-dimensional gel electrophoresis.
Current analytical techniques in protein identification by mass spectrometry are based on the generation of peptide mass maps or sequence tags that are idiotypic for the protein sequence. This work reports on the development of the use of mass spectrometric methods for protein identification in research on metabolic pathways of a genetically modified strain of the baker's yeast Saccharomyces cerevisiae. This study describes the use of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass mapping and liquid chromatography/quadrupole time-of-flight electrospray ionization tandem mass spectrometry (LC/Q-TOF-ESI-MS/MS) sequence tag analysis in identification of yeast proteins separated by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE). ⋯ Mass mapping as a rapid, high-throughput method was in most cases sensitive enough for identification. LC/MS/MS was found to be more sensitive and to provide more accurate data, and was very useful when analyzing small amounts of sample. Even one sequence tag acquired by this method could be enough for unambiguous identification, and, in the present case, successfully identified a point mutation.
-
Rapid Commun. Mass Spectrom. · Jan 2001
On-line measurement of the absolute humidity of air, breath and liquid headspace samples by selected ion flow tube mass spectrometry.
We describe how selected ion flow tube mass spectrometry (SIFT-MS) can be used to determine the absolute humidity of air, breath and liquid headspace samples. This involves the determination of the relative count rates of the H3O+ ions and those H3O+.(H2O)(1,2,3) hydrate ions that inevitably form in the helium carrier gas when humid samples are being analysed by SIFT-MS using H3O+ precursor ions. ⋯ Thus, we show that the humidity of breath and liquid headspace samples, typically at the few percent level, can be directly obtained on-line to the SIFT-MS instrument along with the concentrations of trace gases, which are present at much lower levels. We emphasise the value of parallel humidity measurements in ensuring good real-time sampling of breath and liquid headspace and the value of such measurements to trace gas analysis using SIFT-MS.