Randomized Controlled TrialThe impact of changing people with sleep apnea using CPAP less than 4 h per night to a Bi-level device.
Pressure intolerance is a reason for poor acceptance and subsequent compliance in some patients starting treatment with continuous positive airway pressure (CPAP). In unselected populations initiating CPAP; different types of pressure generating device have not been found to improve compliance. We hypothesized that using Bi-level PAP for patients who reported pressure related discomfort as a cause for poor compliance with CPAP might increase their hours of treatment use. ⋯ The trend suggesting superior compliance with a Bi-level PAP device compared to new CPAP was not significant (p = 0.059) and there were no differences in subjective or objective measures of sleepiness. The results of this study suggest that routine intervention with Bi-level PAP in this group of sub-optimally compliant individuals was not very effective in improving PAP usage. There is however a subgroup of patients who complains of difficulty with exhalation; where favorable trends towards improved compliance were observed on Bi-level PAP.