Cytokine
-
This study was undertaken to investigate whether sequential measurement of blood interleukin (IL)-6 levels using chemiluminescent enzyme immunoassay (CLEIA) would be useful for the management of patients with systemic inflammatory response syndrome (SIRS)/sepsis. Forty consecutive patients with SIRS/sepsis admitted to ICU were involved in the study. Blood IL-6 level was measured everyday throughout their ICU stay at the clinical laboratory by CLEIA method. ⋯ There were significant correlation between the peak IL-6 blood level and the lowest platelet count, and between the peak IL-6 blood level and the maximum SOFA score, respectively. The platelet count became lowest 2.0+/-2.0 days later on average, and the SOFA score became maximal 2.5+/-1.4 days later on average following the day when IL-6 reached its peak value. Sequential measurement of blood IL-6 levels by CLEIA is useful in evaluating the severity and in predicting the outcome of the patients with SIRS/sepsis.