Acta anaesthesiologica Scandinavica
-
Acta Anaesthesiol Scand · Jan 1992
Comparative StudyEffectiveness of pressure support ventilation for mechanical ventilatory support in patients with status asthmaticus.
We compared the effects of pressure support ventilation (PSV) with those of assist control ventilation (ACV) on breathing patterns and blood gas exchange in six patients with status asthmaticus. Both PSV and ACV delivered adequate minute ventilation (PSV: 7.5 +/- 1.4 l/min/m2, ACV: 7.3 +/- 1.3 l/min/m2) to correct respiratory acidosis (pH = 7.33 +/- 0.12 during both PSV and ACV) and prevent hypoxia. ⋯ The oxygen cost of breathing estimated by oxygen consumption was equivalent in both modes. We conclude that PSV is effective in supplying tidal volumes adequate to improve hypercarbia at markedly lower airway pressures than ACV.
-
In order to evaluate postoperative pain treatment following thoracic surgery, 214 medical records of patients who were operated during 1986-1988 were examined. Nurses' comments concerning pain and the amounts of analgesics given during the 2 postoperative days were recorded. The 150 patients who were still alive in December 1989 were sent a postal questionnaire which asked about the pain and the efficacy of pain relief they had received after their operation. ⋯ During the first postoperative week little pain was experienced by 60% of the patients, considerable pain by 35% and excruciating pain by 5% of the patients being interviewed. The postoperative pain relief was rated as good in 60% of the answers, satisfactory in 38% and poor in 2%. Persistent post-thoracotomy pain lasting for more than 6 months was reported by 44% of the patients, of whom 66% had received treatment for the pain.
-
Acta Anaesthesiol Scand · Jan 1992
Pulmonary effects of body position, PEEP, and surfactant depletion in dogs.
The influence of position (sphinx, lateral, supine), surfactant depletion, and different positive end-expiratory pressure (PEEP) on functional residual capacity (FRC), series dead space (VdS) and compliance of the respiratory system (Crs) were evaluated in five dogs. Ventilation homogeneity as measured by an index (multiple breath alveolar mixing efficiency), oxygenation, and cardiovascular hemodynamics were additionally examined. The dogs were anesthetized with halothane, paralyzed, and mechanically ventilated. ⋯ Surfactant depletion by lung lavage with 37 degrees C saline caused an immediate and stable decrease in FRC, Crs, and oxygenation (P less than 0.05, respectively) for about 5 h without marked effects on the circulatory system. FRC and VdS increased with increasing PEEP. At the highest PEEP, 10 cmH2O (1 kPa), Crs decreased (P less than 0.05) and ventilation became more uneven, indicating alveolar overdistension.
-
Acta Anaesthesiol Scand · Jan 1992
Effect of continuous interscalene brachial plexus block on diaphragm motion and on ventilatory function.
Interscalene block may cause phrenic nerve block and decreased diaphragmatic motion. We evaluated the effect of continuous interscalene block on ventilatory function and diaphragmatic motion. We studied ten patients scheduled for surgery or manipulation of the shoulder. ⋯ In the other five patients, the amplitude of diaphragmatic motility on the side of the block was only 4-37% of the values before the block. All patients had a clear reduction in forced vital capacity (FVC), forced expiratory volume in 1s (FEV1) and peak expiratory flow (PEF) 3 and 8 h after the block without signs of dyspnoea. In conclusion, in all our patients interscalene block caused an ipsilateral hemidiaphragm paresis, which in five of ten patients persisted until the end of the continuous block.
-
Acta Anaesthesiol Scand · Nov 1991
Comparative StudyA comparison of median frequency, spectral edge frequency, a frequency band power ratio, total power, and dominance shift in the determination of depth of anesthesia.
Five numerical descriptors were derived from the electroencephalogram (EEG), recorded, and processed (Tracor Nomad) during emergence from isoflurane-nitrous oxide anesthesia. The five descriptors (median frequency, spectral edge frequency-90%, total power, a frequency band power ratio, and the ratio of frontal to occipital power) were compared for their ability to predict imminent arousal. Arousal was defined as spontaneous movement, coughing or eye opening. ⋯ For median frequency, spectral edge frequency-90%, total power, and the frequency band power ratio, thresholds that predicted imminent arousal with sensitivities of 90% and specificities of 82-90% could be identified. The data indicate that, even in the favorable circumstances of the present study (uniform anesthetic technique, post hoC identification of thresholds), none of several previously popularized EEG descriptors (median frequency, spectral edge frequency-90%, total power, a frequency band power ratio) can serve as a completely reliable sole predictor of imminent arousal. As presently derived, these EEG descriptors at best provide trend information to be used in concert with other clinical signs of depth of anesthesia.