Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter.
The CLOSE protocol combines ablation index (AI) and ≤6 mm interlesion distance using standard power settings for the treatment of atrial fibrillation (AF). The purpose was to compare the safety and efficacy of a conventional CLOSE and a higher power shorter duration (HPSD)-CLOSE pulmonary vein isolation (PVI) strategy. ⋯ A higher-power short duration approach can shorten a CLOSE procedure and reduce ablation time without having a negative impact on safety or efficiency.
-
J. Cardiovasc. Electrophysiol. · Nov 2019
Case ReportsAutomated external defibrillator use in a previously healthy 31-day-old infant with out-of-hospital cardiac arrest due to ventricular fibrillation.
Current resuscitation guidelines state that the safety of automated external defibrillators (AEDs) in infants less than 1 year of age is unknown. ⋯ This case represents, to our knowledge, the youngest patient successfully defibrillated by an AED in a nonmedical setting. Although she received two shocks more than 11 J/kg each, she had no apparent myocardial damage at presentation.