Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Sep 2010
A modification of tibial inlay fixation in posterior cruciate ligament reconstruction by interference screw: a biomedical study on calf tibial bone model.
This study presents a modification of tibial inlay technique in posterior cruciate ligament (PCL) reconstruction and evaluates the structural properties of tibial side fixation of the graft, comparing tibial inlay technique and a new modification, that is interference screw fixation of tibial side of the graft in suggested supine position which is more applicable, with less potential intraoperative neurovascular complications. Forty fresh calf knees that were prepared from 20 healthy 3 years old calves which were between 200 and 220 kg were the subject of this study. The tibias were separately used simulating tibial side PCL reconstruction with tibial tuberosity-patellar tendon-patellar bone graft. ⋯ The remaining samples were used for cycling loading. Mann-Whitney U test was used to compare structural properties of each group. No significant differences were observed between two methods at load-to-failure test; but mean elongation at 1,000 cycles of new modification was significantly lower than tibial inlay technique.
-
Arch Orthop Trauma Surg · Sep 2010
Comparative StudyReadmissions after fast-track hip and knee arthroplasty.
With the implementation of fast-track surgery with optimization of both logistical and clinical features, the postoperative convalescence has been reduced as functional milestones have been achieved earlier and consequently length of stay (LOS) in hospital has been reduced. However, it has been speculated that a decrease in LOS may be associated with an increase in readmissions in general, including risk of dislocation after total hip arthroplasty (THA) or manipulation after total knee arthroplasty (TKA). ⋯ Fast-track TKA and THA do not increase the readmission rate. Readmissions are more frequent after TKA than THA, but dislocation after THA and manipulation after TKA do not increase as LOS is decreasing.
-
Arch Orthop Trauma Surg · Sep 2010
Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation.
The treatment of displaced acetabular fractures with formal open reduction and internal fixation has gained general acceptance. However, extensile exposure can lead to complications. Two-dimensional fluoroscopy-based computerized navigation for placement of percutaneous screw across non-displaced acetabular fractures has attracted interest by making use of stored patient-specific imaging data to provide real-time guidance in multiple image planes during implant placement. The purpose of the present study was to document early treatment results and complications associated with this new technique and evaluate its clinical application to displaced acetabular fractures amenable to closed or limited open reduction. ⋯ Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based navigation could be applied not only to non-displaced fractures but also to displaced fractures amenable to closed or limited open reduction.
-
Arch Orthop Trauma Surg · Sep 2010
Comparative StudyReduction of radiation dose during radiofrequency denervation of the lumbar facet joints using the new targeting system SabreSource: a prospective study in 20 patients.
Facet joint denervation is a frequently performed technique to treat facet joint syndrome. Most often this technique is used under fluoroscopic guidance implicating high radiation doses for both patients and surgeons. This prospective study was performed to evaluate the effectiveness in reducing radiation dose during radiofrequency ablation therapy of the lumbar facet joints and to evaluate the feasibility and possibilities of the new real time image guidance system SabreSource. ⋯ The SabreSource System reduces radiation exposure and radiation dose in the radiofrequency denervation therapy of the lumbar facet joints and can be applied for other minimally invasive techniques.
-
Arch Orthop Trauma Surg · Sep 2010
Comparative StudyAdjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a comparison of balloon kyphoplasty and vertebroplasty.
It is still controversial whether adjacent level compression fractures after balloon kyphoplasty (BK) and vertebroplasty (VP) should be regarded as the consequence of stiffness achieved by augmentation with bone cement or if the adjacent level fractures are simply the result of the natural progression of osteoporosis. The purpose of this study was to evaluate the adjacent level fracture risk after BK as compared with VP and to determine the possible dominant risk factor associated with new compression fractures. ⋯ Our results indicate that BK and VP are methods with a low risk of adjacent level fractures. The most important factors for new VCFs after a percutaneous augmentation procedure are the degree of osteoporosis and altered biomechanics in the treated area of the spine due to resistant kyphosis. These results suggest that the adjacent vertebrae would fracture eventually, even without the procedure. BK and VP offer a comparable rate of pain relief.