Journal of magnetic resonance imaging : JMRI
-
J Magn Reson Imaging · Oct 2007
Gadobenate dimeglumine-enhanced MR angiography: Diagnostic performance of four doses for detection and grading of carotid, renal, and aorto-iliac stenoses compared to digital subtraction angiography.
To determine the diagnostic performance of contrast-enhanced MR angiography (CE-MRA) with four doses of gadobenate dimeglumine for detection of significant steno-occlusive disease of the carotid, renal, and pelvic vasculature. ⋯ Significantly better diagnostic performance on CE-MRA of the renal, pelvic, and carotid arteries is achieved with a gadobenate dimeglumine dose of 0.1 mmol/kg bodyweight.
-
The principles of contrast mechanisms and fast pulse sequences underlying neurological and neuroradiological application of MRI are introduced in this part of a two-part review. In particular, the relaxation time constants T(1), T(2), and T(2) (*) are introduced, along with pulse sequences harnessing their contrast, spin-echo, fast spin echo (FSE), inversion recovery (IR), gradient recalled echo (GRE), and echo planar imaging (EPI). The use of gadolinium (Gd)-based contrast is discussed in both T(1)- and T(2) (*)-weighted sequences. ⋯ T(2) (*) sensitivity is discussed as both a source of artifact as well as a contrast mechanism (perfusion imaging with contrast agents, susceptibility weighted imaging [SWI], and blood oxygenation level dependent [BOLD] imaging). Finally, the contrast mechanism of diffusion is introduced, as well as the concept of anisotropy. From these principles, the other part of this two-part review draws upon the pulse sequences and contrast mechanisms to design disease and indication-specific protocols for state-of-the-art clinical use.
-
J Magn Reson Imaging · Oct 2007
Range of ventricular dimensions and function by steady-state free precession cine MRI in repaired tetralogy of Fallot: right ventricular outflow tract patch vs. conduit repair.
To characterize the range of biventricular size and function evaluated by steady-state free precession (SSFP) cine magnetic resonance (MR) in a large cohort of patients with repaired tetralogy of Fallot (TOF), and to compare these measurements in those with a right ventricular outflow tract (RVOT) patch vs. a right ventricle-to-pulmonary artery (RV-PA) conduit. ⋯ This study provides the range and distribution of biventricular size and function, and PR measured by MRI in a large contemporary cohort of patients with repaired TOF, and demonstrates important variations in RV mechanics between patients repaired with a RVOT patch and those with an RV-PA conduit.
-
J Magn Reson Imaging · Oct 2007
Interleaved water and fat imaging and applications to lipid quantitation using the gradient reversal technique.
To implement and evaluate the gradient reversal-based chemical shift imaging technique to obtain qualitative and quantitative spatially-registered fat and water images with high imaging efficiency at very high field. ⋯ The proposed MRI technique permits interleaved water and fat imaging, with which spectrally well-separated water and fat images at the identical slice locations could be obtained in a single acquisition without increasing scan time. The technique could be used for in vivo quantitative mapping of lipid content and applied to investigations using small animal experiment models.
-
J Magn Reson Imaging · Oct 2007
Comparative StudySTIR turbo SE MR imaging vs. coregistered FDG-PET/CT: quantitative and qualitative assessment of N-stage in non-small-cell lung cancer patients.
To conduct a prospective comparison of the accuracy of short inversion time (TI) inversion-recovery (STIR) turbo spin-echo (SE) imaging and coregistered 2-[fluorine-18] fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) with computed tomography (CT) (coregistered FDG-PET/CT) to assess the N-stage in non-small-cell lung cancer (NSCLC) patients. ⋯ STIR turbo SE imaging is at least as valid as coregistered FDG-PET/CT for quantitative and qualitative assessment of the N-stage for NSCLC patients.