Multicenter StudyWhole-body MRI-DWI for assessment of residual disease after completion of therapy in lymphoma: A prospective multicenter study.
To assess the performance of whole-body MRI including diffusion-weighted imaging (whole-body MRI-DWI) for the detection of residual disease after completion of treatment in lymphoma patients. ⋯ Our initial results suggest that visual whole-body MRI-DWI analysis has a very good sensitivity for detecting viable residual lesions after completion of therapy but lacks specificity. ADC measurements could potentially increase the specificity of whole-body MRI.
-
J Magn Reson Imaging · Dec 2015
Increased speed and image quality in single-shot fast spin echo imaging via variable refocusing flip angles.
To develop and validate clinically a single-shot fast spin echo (SSFSE) sequence utilizing variable flip angle refocusing pulses to shorten acquisition times via reductions in specific absorption rate (SAR) and improve image quality. ⋯ vrfSSFSE increases speed at 3T over conventional SSFSE via reduced SAR, and when combined with full-Fourier acquisition can improve image quality, although with some increased sensitivity to cardiac motion-related signal loss.
-
J Magn Reson Imaging · Dec 2015
Subcortical gray matter segmentation and voxel-based analysis using transverse relaxation and quantitative susceptibility mapping with application to multiple sclerosis.
To investigate subcortical gray matter segmentation using transverse relaxation rate (R2 *) and quantitative susceptibility mapping (QSM) and apply it to voxel-based analysis in multiple sclerosis (MS). ⋯ Automatic segmentation of iron-rich deep gray matter can be improved by incorporating QSM. Voxel-based evaluation yielded increased R2 * and QSM in MS subjects in all four nuclei studied with R2 *, benefiting the most from localized analysis over whole-structure measures.
-
J Magn Reson Imaging · Dec 2015
Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.
Cardiac MRI is routinely performed for quantification of shunt flow in patients with anomalous pulmonary veins, but can be technically-challenging to perform. Four-dimensional phase-contrast (4D-PC) MRI has potential to simplify this exam. We sought to determine whether 4D-PC may be a viable clinical alternative to conventional 2D phase-contrast MR imaging. ⋯ Shunt flow may be reliably quantified with 4D-PC MRI, either indirectly or with detailed delineation of flow from multiple shunts. The 4D-PC may be a more accurate alternative to conventional MRI.
-
J Magn Reson Imaging · Dec 2015
Comparative StudyComparing tract-based spatial statistics and manual region-of-Interest labeling as diffusion analysis methods to detect white matter abnormalities in infants with hypoxic-Ischemic encephalopathy.
To compare manual region of interest (ROI) labeling and tract-based spatial statistics (TBSS) by their ability to detect group-wise differences in fractional anisotropy (FA) in the neonatal brain. ⋯ Manual ROI labeling and TBSS are comparable methods of diffusion analysis to detect group differences in FA in the neonatal brain.