Journal of magnetic resonance imaging : JMRI
-
To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution. ⋯ Parallel imaging using ASSET-enhanced T2W SSFSE and T1W 3D SPGR improves the ability to detect significant colon polyps in an MRC phantom model.
-
J Magn Reson Imaging · Sep 2008
Visualization of the protective ability of a free radical trapping compound against rat C6 and F98 gliomas with diffusion tensor fiber tractography.
To apply fiber tractography to assess the effect of a possible antiglioma drug, phenyl N-tert-butyl nitrone (PBN), on glioma-affected neuronal fibers. The fiber tractography method was able to differentiate between different tumor types, such as the C6 and F98 rat glioma models. ⋯ By noninvasively monitoring the degree of neuronal fiber integrity and connectivity with the use of neuronal fiber tractography, we were able to evaluate the protective effect of PBN against invasive glioma growth in rat brains. PBN provided protection of the neuronal fibers against tumor-induced ischemia and tumor invasion.
-
J Magn Reson Imaging · Sep 2008
Complex threshold method for identifying pixels that contain predominantly noise in magnetic resonance images.
To create a robust means to remove noise pixels using complex data. ⋯ The joint use of both magnitude and phase images helps to improve the removal of noise points in magnetic resonance images. This can prove useful in automating the visualization of phase images without the highly distractive phase noise in noise regions. Also, it is useful in susceptibility weighted imaging when taking the minimum intensity projections of variably sized regions.
-
J Magn Reson Imaging · Sep 2008
Multicenter StudyEvaluation of cardiac biventricular segmentation from multiaxis MRI data: a multicenter study.
To validate a volumetric biventricular segmentation solution for multiaxis cardiac magnetic resonance (CMR) images. ⋯ Fully automatic segmentation produces good results in the assessment of left ventricular volume andendocardial border. Two minutes of user interaction are needed to obtain accurate results for the right ventricle.
-
J Magn Reson Imaging · Sep 2008
Comparative StudyFree-breathing, nongated real-time delayed enhancement MRI of myocardial infarcts: a comparison with conventional delayed enhancement.
To compare a free-breathing, nongated, and black-blood real-time delayed enhancement (RT-DE) sequence to the conventional inversion recovery gradient echo (IR-GRE) sequence for delayed enhancement MRI. ⋯ RT-DE can be used for delayed enhancement imaging during free-breathing and without cardiac gating.