Journal of magnetic resonance imaging : JMRI
-
To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution. ⋯ Parallel imaging using ASSET-enhanced T2W SSFSE and T1W 3D SPGR improves the ability to detect significant colon polyps in an MRC phantom model.
-
J Magn Reson Imaging · Sep 2008
Multicenter StudyEvaluation of cardiac biventricular segmentation from multiaxis MRI data: a multicenter study.
To validate a volumetric biventricular segmentation solution for multiaxis cardiac magnetic resonance (CMR) images. ⋯ Fully automatic segmentation produces good results in the assessment of left ventricular volume andendocardial border. Two minutes of user interaction are needed to obtain accurate results for the right ventricle.
-
J Magn Reson Imaging · Sep 2008
Comparative StudyFree-breathing, nongated real-time delayed enhancement MRI of myocardial infarcts: a comparison with conventional delayed enhancement.
To compare a free-breathing, nongated, and black-blood real-time delayed enhancement (RT-DE) sequence to the conventional inversion recovery gradient echo (IR-GRE) sequence for delayed enhancement MRI. ⋯ RT-DE can be used for delayed enhancement imaging during free-breathing and without cardiac gating.
-
J Magn Reson Imaging · Sep 2008
Assessment of fluctuating velocities in disturbed cardiovascular blood flow: in vivo feasibility of generalized phase-contrast MRI.
To evaluate the feasibility of generalized phase-contrast magnetic resonance imaging (PC-MRI) for the noninvasive assessment of fluctuating velocities in cardiovascular blood flow. ⋯ PC-MRI IVSD mapping is able to detect flow abnormalities in a variety of human cardiovascular conditions and shows promise for the quantitative assessment of turbulence. This approach may assist in clarifying the role of disturbed hemodynamics in cardiovascular diseases.
-
J Magn Reson Imaging · Sep 2008
Dynamic contrast-enhanced (DCE) derived transfer coefficient (ktrans) is a surrogate marker of matrix metalloproteinase 9 (MMP-9) expression in brain tuberculomas.
To correlate dynamic contrast-enhanced (DCE) MRI derived perfusion indices with immunohistochemically obtained vascular endothelial growth factor (VEGF) and matrix metalloproteinase-9 (MMP-9) in a cellular fraction of brain tuberculomas (BT). ⋯ We conclude that the expression of MMP-9, a marker of BBB disruption and disease activity in BT correlates with DCE-derived ktrans and thus has the potential to be used as its surrogate marker.