Journal of magnetic resonance imaging : JMRI
-
To describe what, if any, specific long T(2)-related abnormalities occur in the white matter of subjects with either phenylketonuria (PKU) or multiple sclerosis (MS). ⋯ This study supports the usefulness of increasing the data acquisition window of the multiecho T(2) relaxation sequence to better characterize the T(2) decay from pathological brain.
-
J Magn Reson Imaging · Oct 2007
High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI).
To investigate an alternative approach to correct for flip angle inaccuracies in the driven equilibrium single pulse observation of T1 (DESPOT1) T1 mapping method. ⋯ The described approach, dubbed DESPOT1-HIFI, permits whole-brain T1 mapping at 3T, with 1 mm(3) isotropic voxels, in a clinically feasible time (approximately 10 minutes) with T1 accuracy greater than 5% and with high precision.
-
J Magn Reson Imaging · Oct 2007
Simultaneous myocardial and fat suppression in magnetic resonance myocardial delayed enhancement imaging.
To develop a method for fat suppression in myocardial delayed enhancement (MDE) studies that achieves effective signal intensity reduction in fat but does not perturb myocardial signal suppression. ⋯ The results indicate this modular-type approach optimizes fat suppression in myocardial delayed enhancement studies but does not perturb the basic IR pulse sequence or change basic acquisition parameters.
-
J Magn Reson Imaging · Sep 2007
Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal filtering (TSENSE).
To investigate the parallel acquisition technique sensitivity encoding incorporating temporal filtering (TSENSE) with three saturation-recovery (SR) prepared pulse sequences (SR turbo fast low-angle shot [SR-TurboFLASH], SR true fast imaging with steady precession [SR-TrueFISP], and SR-prepared segmented echo-planar-imaging [SR-segEPI]) for semiquantitative first-pass myocardial perfusion imaging. ⋯ Semiquantitative myocardial perfusion imaging can significantly benefit from TSENSE due to shorter acquisition times and increased linearity of the pulse sequences. Among the three pulse sequences tested, SR-TrueFISP yielded best image quality. SR-segEPI proved to be an interesting alternative due to shorter acquisition times, higher linearity and fewer dark-banding artifacts.