Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
-
Ultrasound Obstet Gynecol · Jan 2017
Comparative StudyCardiac output assessment in pregnancy: comparison of two automated monitors with echocardiography.
To compare non-invasive hemodynamic measurements obtained in pregnant and postpartum women using two automated cardiac output monitors against those obtained by two-dimensional (2D) transthoracic echocardiography (TTE). ⋯ We found good agreement of both USCOM and NICOM when compared with 2D-TTE, specifically in the third trimester of pregnancy. Both devices had good intraobserver repeatability and either had good interobserver reproducibility or were operator-independent. Future studies should take into account the significant differences in the precise maternal hemodynamic values obtained by these devices, and consider developing device-specific reference ranges in pregnancy and the postpartum period. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
-
Ultrasound Obstet Gynecol · Jan 2017
Observational StudySerial hemodynamic monitoring to guide treatment of maternal hypertension leads to reduction in severe hypertension.
To examine whether treatment for hypertension in pregnancy that is guided by serial monitoring of maternal central hemodynamics leads to a reduction in the rate of severe hypertension, defined as blood pressure ≥ 160/110 mmHg; and to assess the distinct longitudinal hemodynamic profiles associated with beta-blocker monotherapy, vasodilator monotherapy and dual agent therapy, and their relationships with outcomes, including fetal growth restriction. ⋯ El tratamiento que tuvo en cuenta los resultados del seguimiento hemodinámico en serie redujo la tasa de hipertensión prenatal grave del 18% al 3,8%. Al 77% de las mujeres se les recetó inicialmente un y al 23% un vasodilatador. El grupo que mantuvo un buen control de la presión arterial con monoterapia de beta-bloqueantes logró mejores resultados fetales y maternos. Este grupo tuvo menor presión arterial al inicio y durante toda la gestación, mostró un gasto cardíaco en buen estado y tuvo las tasas más bajas de restricción del crecimiento fetal. Los grupos que requirieron terapia dual para controlar su presión arterial mostraron persistentemente una mayor presión arterial y un mayor ritmo de restricción del crecimiento fetal. Los grupos que requirieron tratamiento vasodilatador debido a los altos niveles de resistencia vascular periférica, tanto al inicio como durante el embarazo, representaron el 81% de los casos con restricción del crecimiento fetal. CONCLUSIÓN: El uso de un seguimiento hemodinámico en serie en el embarazo como guía para el tratamiento de la hipertensión reduce significativamente la tasa de hipertensión severa y permite la identificación de embarazos con hipertensión de alta resistencia y malos resultados, asociados con una mayor tasa de restricción del crecimiento fetal. : (≥ 160/110 mmHg);β、,()。 : 。52、,β。β。,(<140/90 mmHg),logistic,。,。,(β)。 : ,18%3.8%。77%β,23%。β。,,。,。,81%。 : ,,、。.
-
Ultrasound Obstet Gynecol · Dec 2016
Review Meta AnalysisSystematic review and meta-analysis of persistent left superior vena cava on prenatal ultrasound: associated anomalies, diagnostic accuracy and postnatal outcome.
To quantify the prevalence of chromosomal anomalies in fetuses with persistent left superior vena cava (PLSVC), assess the strength of the association between PLSVC and coarctation of the aorta and ascertain the diagnostic accuracy of antenatal ultrasound in correctly identifying isolated cases of PLSVC. ⋯ La VCSIP está comúnmente asociada a AIC, AEC y anomalías cromosómicas. Los fetos con VCSIP aislada deben ser objeto de seguimiento durante todo el embarazo, con el fin de descartar la coartación aórtica. Como la mayoría de los datos de esta revisión proceden de embarazos de alto riesgo, es probable que la tasa de anomalías asociadas sea más alta que la de la población general de fetos con VCSIP, por lo que se necesitan más datos.
-
Ultrasound Obstet Gynecol · Dec 2016
Review Meta Analysis Comparative StudyStrategies for improving outcome of assisted reproduction in women with polycystic ovary syndrome: systematic review and meta-analysis.
To identify, appraise and summarize the current evidence regarding the efficacy of strategies aimed at improving assisted reproductive techniques in women with polycystic ovary syndrome (PCOS). ⋯ Se cribaron 1021 registros, de los que se evaluaron por completo 173, para finalmente incluir 66 estudios en el análisis cuantitativo. Aunque se evaluaron muchas intervenciones diferentes, en general la calidad de los estudios fue baja. Se observó evidencia de calidad moderada de que no hay diferencias relevantes clínicamente en las tasas de nacimientos vivos/embarazos en curso (riesgo relativo (RR): 0,95 (IC 95%, 0,84-1,08)), o de embarazos confirmados ecográficamente (RR: 1,02 (IC 95%, 0,91-1,15)), cuando se comparan los protocolos de antagonistas y agonistas para la estimulación ovárica. Además, se encontró evidencia de baja calidad en que la metformina mejora las tasas de nacimientos vivos/embarazos en curso (RR: 1,28 (IC 95%, 1,01-1,63)) y de embarazos confirmados ecográficamente (RR: 1,26 (IC 95%, 1,04-1,53)) en comparación con un placebo o la no intervención. Se encontró también evidencia de baja calidad en que no hay diferencias relevantes clínicamente en las tasas de nacimientos vivos/embarazos en curso (RR: 1,03 (IC 95%, 0,80-1,34)) y las tasas de embarazos confirmados ecográficamente (RR: 0,99 (IC 95%, 0.81-1,22)) al comparar la gonadotropina menopáusica humana para la inducción de la ovulación y la preparación artificial con el valerato de estradiol para preparar el endometrio para la transferencia de embriones congelados (TEC). La baja calidad de la evidencia sugiere que el manitol, en comparación con la no intervención (RR: 0,54 (IC 95%, 0,39-0,77)), y los protocolos de antagonistas, en comparación con los protocolos de agonistas (RR: 0,63 (IC 95%, 0,49-0,80)), reducen las tasas de SHO. CONCLUSIÓN: Hay evidencia de calidad baja a moderada que sugiere que los protocolos de antagonistas son preferibles a los de agonistas, ya que reducen la tasa de SHO sin interferir con el embarazo confirmado ecográficamente y los nacimientos vivos en las mujeres con SOP. Además, existe evidencia de baja calidad que indica un beneficio del uso de metformina como aporte suplementario en embarazos confirmados ecográficamente y en nacimientos vivos; y que la inducción de la ovulación y la administración de estradiol parecen ser igualmente eficaces para la preparación del endometrio antes de la TEC en mujeres con SOP. Para el resto de procedimientos, la evidencia es de muy baja calidad, y por ello no permite extraer conclusiones importantes.
-
Ultrasound Obstet Gynecol · Dec 2016
Cervical cerclage for preterm birth prevention in twin gestation with short cervix: a retrospective cohort study.
To determine if cervical cerclage reduces the rate of spontaneous early preterm birth in cases of dichorionic-diamniotic (DCDA) twin gestation with an ultrasound-detected short cervix. ⋯ In DCDA twin gestation with a short cervix, treatment with cervical cerclage may reduce the rate of early preterm birth. The findings suggest the need for adequate randomized controlled trials on cerclage in twin gestations with a short cervix. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.