European radiology
-
Multicenter Study
Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy.
Our objective was to evaluate, in a routine clinical setting, the role of spiral CT as a second procedure in patients with clinically suspected pulmonary embolism (PE) and abnormal perfusion scan. We prospectively studied the role of spiral CT in 279 patients suspected of PE. All patients started their diagnostic algorithm with chest radiographs and perfusion scintigraphy. ⋯ In the high-probability group, sensitivity and specificity increased to 97 and 100%, respectively, with a prevalence of 90%. In the non-high probability-group sensitivity and specificity decreased to 61 and 89%, respectively, with a prevalence of 25%. In a routine clinical setting single-detector spiral CT technology has limited value as a second diagnostic test because of low added value in patients with a high-probability lung scan and low sensitivity in patients with non-high-probability lung scan result.