It is often stated that venovenous extracorporeal membrane oxygenation (VV ECMO) should not be used in inotrope dependent patients. It is our practice to use VV ECMO in most patients with respiratory failure even though many of these patients are receiving significant doses of inotropes. Our objective was to review the mode of ECMO in relation to precannulation doses of inotropes administered to neonates treated with ECMO for respiratory failure. ⋯ Mean arterial blood pressure remained above precannulation levels in both groups. VV ECMO allows safe treatment of neonatal respiratory failure in the presence of significant inotropic support. We recommend VV ECMO for neonatal respiratory failure in all cases except where double lumen cannulation is impossible or when septic shock is refractory to inotropic support (i.e., mean blood pressure < 35 mm Hg despite inotrope score of > 100).
-
Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. ⋯ Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.
-
Recently, venovenous extracorporeal life support (VVECLS) using a double lumen catheter has been clinically used to avoid neurologic complications in the treatment of respiratory failure for neonates. However, recirculation, which is a limiting factor for oxygen delivery, still exists, and thus it does not contribute to oxygenation of the patient. We developed a newly designed double lumen catheter with a double balloon (DBDL) catheter for ECLS vascular access and performed two animal preliminary experiments in normal and hypoxic dog models (normal ventilation and one lung ventilation experiments) to investigate whether the DBDL catheter could prevent recirculation and maintain oxygen delivery to systemic circulation. ⋯ At balloon inflation, the value of PaO2 at 6 hours after VVECLS initiation was significantly higher than that at balloon deflation. A newly designed DBDL catheter for ECLS vascular access successfully reduced recirculation and maintained oxygen delivery to systemic circulation during VVECLS. These results suggest that a high bypass flow may not be necessarily required in terms of oxygen delivery to systemic circulation when the DBDL catheter was used as an ECLS vascular access.
-
The aim of this study was to evaluate the function of the AbioCor artificial heart implanted in calves that underwent treadmill exercise testing and to investigate the cardiovascular and metabolic responses during exercise. Six calves were implanted with the AbioCor. One week after surgery, exercise training was undertaken and animals were put on a treadmill at a speed of 0.5-1.0 mph, with the AbioCor operating at the maximum heart rate of 150 beats per minute. ⋯ The index of metabolic adequacy remained higher than 2.0, indicating that there was no substantial transition to anaerobic metabolism during exercise. There was an increased extraction of oxygen during exercise to meet the increased energy demands. Our study demonstrated that animals implanted with the AbioCor heart were able to maintain aerobic metabolism during low levels of exercise testing.