ASAIO journal : a peer-reviewed journal of the American Society for Artificial Internal Organs
-
Extracorporeal membrane oxygenation (ECMO) is based on technology that has been used clinically for decades. Largely because of its widespread use in pediatric patients with respiratory failure, familiarity with this technology has established ECMO as the most commonly used form of circulatory support for children. ⋯ Although traditionally lagging behind development for adult applications, the use of ventricular assist devices (VADs) is expanding in pediatrics. Of particular interest, a number of new VADs designed specifically for children are becoming available, while early development of some innovative devices for pediatric circulatory support is currently underway.
-
In this retrospective study, we compared the effects of colloid versus crystalloid fluid replacement on the clinical signs of capillary leakage syndrome in 30 neonates with pulmonary hypertension due to meconium aspiration syndrome on venoarterial membrane oxygenation (VA-ECMO). Before 2000, 15 neonates received volume replacement with a pasteurized plasma protein solution (3.8% albumin); after 2000, 15 neonates received normal saline. Patient characteristics and pre-ECMO values did not differ between the two groups. ⋯ Serum colloid osmotic pressure, albumin, urea nitrogen, and creatinine were significantly higher in the colloid group (p < 0.0001, < 0.0001, < 0.001, and < 0.05, respectively). Duration of VA-ECMO, of artificial ventilation after ECMO treatment, and the mortality rate did not differ between the two groups. We conclude that volume replacement with crystalloids in neonates on VA-ECMO aggravated the edema in a preexisting situation of capillary leakage syndrome, whereas volume replacement with colloids could impair the kidney function.
-
Since 1992, miniaturized pulsatile air-driven ventricular assist devices (VADs), "Berlin Heart," have been used at many institutions (36 cases in North America in 19 different institutions) for pediatric use. Heparin-induced thrombocytopenia (HIT II) is a significant complication rarely reported in the setting of adult VAD support; no similar report exists concerning pediatric VAD support. We report on a 13-month-old, 8.1 kg girl who required LVAD support for cardiogenic shock of unclear etiology. ⋯ On postimplant day 10, the pump required replacement because of concerns about an inlet valve thrombus; the explanted device demonstrated a nearly occlusive clot not appreciable from external inspection. Simultaneously, HIT II was diagnosed as a result of hematology workup for persistent thrombocytopenia. We discuss the unique challenges posed by HIT II complicating pediatric VAD support and in relation to the heparin coating of the device.