ASAIO journal : a peer-reviewed journal of the American Society for Artificial Internal Organs
-
De novo aortic valve insufficiency (AI) is a frequent occurrence in patients supported with left ventricular assist device (LVAD). The European version of the HeartWare LVAD has intermittent low-speed software (lavare cycle) to facilitate intermittent aortic valve opening. We examined aortic valve opening status and prevalence of AI in patients supported with HeartWare LVAD and activated lavare cycle. ⋯ An average pump flow, speed, and mean arterial pressure of 4.4 ± 0.6 L/min, 2,585 ± 147 rpm, and 88 ± 11 mmHg were documented, respectively. Aortic valve opening was persistently seen in 22 patients (65%). Aortic valve opening is frequent, and the development of > mild AI seems to be rare in patients supported with HeartWare LVAD.
-
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) has saved thousands of newborns. Population comparisons for research and quality initiatives require risk-matching, but no indices exist for this population. We sought to create a pre-ECMO risk index using the registry data from the Extracorporeal Life Support Organization. ⋯ Our developed indices provide the first steps towards risk-adjusting patients for meaningful comparisons amongst patient populations. There may be additional clinically relevant measures, both pre- and on-ECMO, which could provide better predictive capability. Future work will focus on finding these additional measures and expansion of our techniques to include other patient populations.
-
Extracorporeal life support (ECLS) is fast becoming more common place for use in adult patients failing mechanical ventilation. Management of coagulation and thrombosis has long been a major complication in the use of ECLS therapies. ⋯ We describe our methods of MO dissection, sample preparation, image capture, and results. Of the five MOs analyzed, those that received continuous heparin infusion showed very little thrombosis formation or other clot material, whereas those that were used with only initial heparin bolus showed readily apparent thrombotic material.
-
Mechanical ventilation support for acute respiratory distress syndrome (ARDS) patients involves the use of low tidal volumes and positive end-expiratory pressure. Nevertheless, the optimal ventilator strategy for ARDS patients undergoing extracorporeal membrane oxygenation (ECMO) therapy remains unknown. A retrospective analysis of a consecutive series of adult ARDS patients treated with V-V ECMO from October 2012 to May 2015 was performed. ⋯ Also, a 1 unit increase in PEEP was associated with a 36.2% decrease in the odds of 30 day survival (95% CI = 10.8-54.4%, p = 0.009). Among ARDS patients undergoing ECMO therapy, only plateau pressure is associated with hospital survival. Plateau pressure and PEEP are both associated with 30 day survival posthospital discharge.
-
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) has experienced an increased use in acute cardiac failure. There are some reports on negative effects of VA-ECMO on cardiac function, such as left ventricular (LV) dilatation and cardiac stun, but the support in the literature is scarce. This study investigates the effects of experimental VA-ECMO on LV function in both peripheral and central cannulation. ⋯ The site of cannulation had no impact on the LV response to ECMO. In conclusion, VA-ECMO increased LV volumes and reduced LV function, irrespective of cannulation site in this experimental model. Reduced LV ejection fraction and stroke work indicated LV dysfunction during ECMO.