ASAIO journal : a peer-reviewed journal of the American Society for Artificial Internal Organs
-
Extracorporeal membrane oxygenation (ECMO) is used as a lifesaving rescue treatment in refractory respiratory or cardiac failure. During venovenous (VV) ECMO, the presence of recirculation is known, but quantification and actions to minimize recirculation after measurement are to date not routinely practiced. In the current study, we investigated the effect of draining cannula design on recirculation fraction (Rf) during VV ECMO; conventional mesh cannula was compared with a multistage cannula. ⋯ Pooled data in cases improved from adjustment showing reduced Rf by 7%. In conclusion, the choice of cannula matters, as does adjustment of the draining cannula position during atrio-femoral VV ECMO. By utilizing the ultrasound dilution technique to measure Rf before and after repositioning, effective ECMO flow can be improved for a more effective ECMO treatment.
-
De novo aortic valve insufficiency (AI) is a frequent occurrence in patients supported with left ventricular assist device (LVAD). The European version of the HeartWare LVAD has intermittent low-speed software (lavare cycle) to facilitate intermittent aortic valve opening. We examined aortic valve opening status and prevalence of AI in patients supported with HeartWare LVAD and activated lavare cycle. ⋯ An average pump flow, speed, and mean arterial pressure of 4.4 ± 0.6 L/min, 2,585 ± 147 rpm, and 88 ± 11 mmHg were documented, respectively. Aortic valve opening was persistently seen in 22 patients (65%). Aortic valve opening is frequent, and the development of > mild AI seems to be rare in patients supported with HeartWare LVAD.
-
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) has saved thousands of newborns. Population comparisons for research and quality initiatives require risk-matching, but no indices exist for this population. We sought to create a pre-ECMO risk index using the registry data from the Extracorporeal Life Support Organization. ⋯ Our developed indices provide the first steps towards risk-adjusting patients for meaningful comparisons amongst patient populations. There may be additional clinically relevant measures, both pre- and on-ECMO, which could provide better predictive capability. Future work will focus on finding these additional measures and expansion of our techniques to include other patient populations.
-
Extracorporeal life support (ECLS) is fast becoming more common place for use in adult patients failing mechanical ventilation. Management of coagulation and thrombosis has long been a major complication in the use of ECLS therapies. ⋯ We describe our methods of MO dissection, sample preparation, image capture, and results. Of the five MOs analyzed, those that received continuous heparin infusion showed very little thrombosis formation or other clot material, whereas those that were used with only initial heparin bolus showed readily apparent thrombotic material.
-
Mechanical ventilation support for acute respiratory distress syndrome (ARDS) patients involves the use of low tidal volumes and positive end-expiratory pressure. Nevertheless, the optimal ventilator strategy for ARDS patients undergoing extracorporeal membrane oxygenation (ECMO) therapy remains unknown. A retrospective analysis of a consecutive series of adult ARDS patients treated with V-V ECMO from October 2012 to May 2015 was performed. ⋯ Also, a 1 unit increase in PEEP was associated with a 36.2% decrease in the odds of 30 day survival (95% CI = 10.8-54.4%, p = 0.009). Among ARDS patients undergoing ECMO therapy, only plateau pressure is associated with hospital survival. Plateau pressure and PEEP are both associated with 30 day survival posthospital discharge.