American journal of clinical pathology
-
Am. J. Clin. Pathol. · Apr 2013
Activated partial thromboplastin time and anti-xa measurements in heparin monitoring: biochemical basis for discordance.
We examined the concordance of heparin levels measured by a chromogenic anti-Xa assay and the activated partial thromboplastin time (APTT) during unfractionated heparin therapy (UFH) and the biochemical basis for differences between these measures. We also investigated the endogenous thrombin potential (ETP) as a possible measure of anticoagulation. Paired measures of anti-Xa and APTT were performed on 569 samples from 149 patients on UFH. ⋯ ETP correlated with anticoagulation status and UFH dose. In conclusion, factor II and VIII activity contributes to discordance between APTT and anti-Xa results. ETP measurements may provide an additional assessment of anticoagulation status.