Acta paediatrica
-
Comparative Study
Comparison of EML 105 and advantage analysers measuring capillary versus venous whole blood glucose in neonates.
Near-patient blood glucose monitoring is an essential component of neonatal intensive care but the analysers currently used are unreliable and inaccurate. The aim of this study was to compare a new glucose electrode-based analyser (EML 105) and a non-wipe reflectance photometry method (Advantage) as opposed to a recognized laboratory reference method (Hexokinase). We also investigated the effect of sample route and haematocrit on the accuracy of the glucose readings obtained by each method of analysis. ⋯ Both EML 105 and Advantage overestimated plasma glucose, with no significant difference in the performance of either analyser, regardless of the route of analysis. Agreement with plasma glucose was better for venous samples but this was only statistically significant when EML 105 capillary and venous results were compared. Haematocrit is not a significant confounding factor towards the performance of either EML 105 or Advantage in neonates, regardless of the route of sampling. The margin of overestimation of blood glucose prohibits the recommendation of both EML 105 and Advantage for routine neonatal glucose screening. The consequences include failure accurately to diagnose hypoglycaemia and delays in the instigation of therapeutic measures, both of which may potentially result in an adverse, long-term, neurodevelopmental outcome.
-
To study the experience of, training in, and confidence in the transportation of critically ill neonates amongst paediatric trainees in one UK region. ⋯ Many training-grade paediatricians lack both the experience and training in transporting critically ill neonates, factors that were found to affect their confidence in transferring sick neonates. As the overwhelming majority of neonatal transports in the UK are still arranged by individual units and performed by training-grade paediatricians, concerns regarding both the safety and effectiveness of the current service provision for the inter-hospital transfer of critically ill neonates remain valid.
-
Hepatic technetium-99m-mebrofenin iminodiacetate (99mTc-mebrofenin IDA) scans and serum gamma-glutamyl transpeptidase (GGTP) have high sensitivity for extrahepatic biliary atresia (EHBA). This study was based on the hypothesis that the interpretation of results of 99mTc-mebrofenin IDA scans and serum GGTP levels in series would result in a reduction of the false positivity observed with these tests individually. The aetiology of neonatal cholestasis in 132 study patients was: 25% (33/132) EHBA, 45.5% (60/132) neonatal hepatitis (NH) with an identifiable cause and 19.7% (26/132) idiopathic NH. Of the various clinical, biochemical and imaging parameters that were significantly different between patient groups, sensitivity for EHBA was: serum GGTP > or = 150 IU l(-1) (100%), 99mTc-mebrofenin IDA scans (100%), pale stools (82.8%) and total serum bilirubin > or = 12 mg dl(-1) (66%). However, specificity ranged from 48.5 to 79%. Of the 63 patients who had non-excreting IDA scans, operative cholangiograms could be avoided on the basis of a specific aetiological diagnosis of NH, made concurrently, in only 9 infants. The rest (54) underwent operative cholangiograms; 21 (39%) of these had patent biliary trees and therefore underwent the procedure unnecessarily. If serum GGTP (< 150 IU l(-1)) had been used as a screen after IDA scanning in these 54 patients, operative cholangiograms could have been avoided in another 12 patients and thereafter only 9/42 (21%) of the operative cholangiograms would have been considered unnecessary. ⋯ A diagnostic algorithm is proposed wherein serum GGTP level (at a cut-off level that maintains 100% sensitivity for EHBA) is used in series with non-excreting 99mTc-mebrofenin IDA scans (for patients with no specific aetiological label). This strategy reduces the false positivity of individual tests.