American journal of ophthalmology
-
Randomized Controlled Trial Comparative Study Clinical Trial
Comparison of preservative-free bupivacaine vs. lidocaine for intracameral anesthesia: a randomized clinical trial and in vitro analysis.
To determine whether intracameral bupivacaine hydrochloride 0.5% is as effective as lidocaine hydrochloride 1.0% in controlling discomfort of patients during phacoemulsification and posterior chamber intraocular lens implantation. In rabbits, corneal endothelial cell function, ultrastructure, and viability were evaluated after in vitro perfusion of bupivacaine 0.5%. ⋯ Clinically, bupivacaine 0.5% is as effective as lidocaine 1.0% for anesthesia during phacoemulsification and posterior chamber intraocular lens implantation. However, in vitro perfusion of bupivacaine 0.5% damaged the corneal endothelium of rabbits except when the drug was diluted 1:1 with glutathione bicarbonate Ringer solution. Surgeons who use 0.2 to 0.5 ml of intracameral bupivacaine 0.5% should be aware of its potential to cause endothelial cell damage because of its lipid solubility. The bupivacaine 0.5% should be diluted at least 1:1 with balanced salt solution before intracameral injection, followed immediately by phacoemulsification. The surgeon should ensure that the bupivacaine 0.5% is nonpreserved and packaged in single-use vials or flip-top containers.
-
Ischemic disorders of the optic nerve head constitute an important cause of visual loss. The optic nerve head is supplied by two main sources of blood flow: the superficial layers by the central retinal artery and the deeper layers by the posterior ciliary arteries. This study was conducted in rhesus monkey eyes to obtain a better understanding of which part of the optic nerve head circulation is measured by laser Doppler flowmetry. ⋯ The findings of this study suggest that the standard laser Doppler flowmetry technique is predominantly sensitive to blood flow changes in the superficial layers of the optic nerve head and less sensitive to those in the prelaminar and deeper regions, and their relative proportions are not known. In this laser Doppler flowmetry technique, the weaker Doppler signal from the deep layers cannot be separated from the dominant signal from the superficial layers to exclusively study the circulation in the deep layers; the latter circulation is of interest in optic nerve head ischemic disorders, including glaucoma. Emerging new optical modalities of the laser Doppler flowmetry technique may help in selectively measuring blood flow in the deeper layers.