European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Proximal screw pullout is a well-recognized problem in anterior scoliosis surgery, with a rate of pseudarthrosis or screw pullout ranging from 15 to 30%. To prevent screw pullout at the top of the construct, the authors have devised the concept of a claw for the top instrumented vertebra. The claw consists of a classic anterior vertebral body screw inserted parallel to the inferior end-plate and in the posterior portion of the vertebral body 8 mm in front of the spine canal. ⋯ This concept can also be extended in the case of early revision for a proximal screw pullout, where it is possible to revise the instrumentation with an offset connector linking the rod to the superior portion of the pedicle where the suprapedicule hook has been inserted. We report two cases where a suprapedicle claw was successfully used in anterior scoliosis correction of a right thoracic curve. Such a concept may represent the solution to proximal screw pullout in anterior scoliosis correction.