Anaesthesia
-
Randomized Controlled Trial Clinical Trial
Assessment of tracheal intubation in children after induction with propofol and different doses of remifentanil.
Tracheal intubating conditions were assessed in 112 children after induction of anaesthesia with propofol and remifentanil 1.0, 2.0 or 3.0 micro g.kg-1. Subjects in a control group were given propofol and mivacurium 0.2 mg.kg-1. Haemodynamic and respiratory parameters were recorded. ⋯ Systolic blood pressure and heart rate increased in response to tracheal intubation in subjects given remifentanil 1.0 micro g.kg-1 and in the control group (p < 0.05). Time to resumption of spontaneous respiration was prolonged in subjects given remifentanil 3.0 micro g.kg-1 (p < 0.001). In conclusion, remifentanil 2 micro g.kg-1 provides acceptable intubating conditions and haemodynamic stability without prolonging the return of spontaneous respiration.
-
Randomized Controlled Trial Clinical Trial
Bougie-assisted difficult airway management in a manikin - the effect of position held on placement and force exerted by the tip.
In a randomised cross-over study, 50 anaesthetists attempted to place a multiple-use bougie in the trachea of a manikin, when holding it at either 20 cm or 30 cm from the tip. A grade 3 laryngoscopic view was simulated. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). ⋯ The peak force exerted by the single-use bougies was two to three times greater than that which could be exerted by the multiple-use bougies (p < 0.0001). Holding the bougie at either 20 or 30 cm distance from the tip is unlikely to influence bougie placement. The single-use bougie is much more likely to cause trauma to tissue during placement, particularly if held close to the tip.
-
Patients with coronary artery disease presenting for major noncardiac surgery may have indications for both peri-operative beta-blockade and haemodynamic optimisation. The combination of peri-operative cardiorespiratory failure and myocardial ischaemia has a grave prognosis. ⋯ There may, therefore, be a place for both peri-operative beta-blockade and haemodynamic optimisation. The indications for peri-operative beta-blockade and haemodynamic optimisation, the effect of acute beta-blockade on cardiac output in patients with coronary artery disease, and the interaction of peri-operative beta-blockade and haemodynamic optimisation are discussed.
-
Comparative Study
Comparison of four different emergency airway access equipment sets on a human patient simulator.
This study used a patient simulator to study the ease of use and efficacy of four currently available cricothyroidotomy sets. We assessed the success of insertion of each piece of equipment and measured the subsequent adequacy of oxygenation and ventilation. ⋯ There was an unacceptably high failure rate in achieving a patent airway when using the 'Transtracheal airway catheter with ENK-flow modulator' and 'Patil's airway'. The pre-assembled and user-friendly 'Quiktrach' set provided the fastest and most effective means of oxygenation in the simulated patient requiring an emergency surgical airway.