Anaesthesia
-
Randomized Controlled Trial Comparative Study
Emergency capnography monitoring: comparing ergonomic design of intensive care unit ventilator interfaces and specific training of staff in reducing time to activation.
Modern ventilators provide capnography monitoring in patients with tracheal tubes, in compliance with national and international recommendations. This technology is often not used when patients' lungs are non-invasively ventilated; however, it should be accessed immediately following tracheal intubation to confirm tube placement. This study assessed the effect of ventilation interface design on the speed with which capnography can be activated by comparing the Dräger Evita 4 and Dräger V500 before and after a specific training episode. ⋯ We used a randomised crossover design, measuring time to monitoring activation, and repeated the study after 3 months. Survival analysis showed significantly quicker activation associated with ventilator choice (V500, p < 0.0001) and training (p = 0.0058). The training improved activation speed with both machines, though this was only significant for the Evita 4 (p = 0.0097).
-
Randomized Controlled Trial
Effects of magnesium sulphate on postoperative coagulation, measured by rotational thromboelastometry (ROTEM(®)).
We investigated the effects of magnesium sulphate on blood coagulation profiles using rotational thromboelastometry in gynaecological patients undergoing pelviscopic surgery. Patients were randomly allocated to the magnesium group (n = 20) or control group (n = 20). ⋯ Postoperative clotting time, clot formation time, α-angle and maximum clot firmness of INTEM, and clot formation time, α-angle, and maximum clot firmness of EXTEM were significantly different between the two groups (p < 0.05). Intra-operative infusion of magnesium sulphate seems to attenuate postoperative hypercoagulability by maintaining magnesium levels at the upper limit of the normal range.
-
Randomized Controlled Trial
Closed and open breathing circuit function in healthy volunteers during exercise at Mount Everest base camp (5300 m).
We present a randomised, controlled, crossover trial of the Caudwell Xtreme Everest (CXE) closed circuit breathing system vs an open circuit and ambient air control in six healthy, hypoxic volunteers at rest and exercise at Everest Base Camp, at 5300 m. Compared with control, arterial oxygen saturations were improved at rest with both circuits. ⋯ During exercise, the CXE closed circuit improved median (IQR [range]) saturation from a baseline of 70.8% (63.8-74.5 [57-76]%) to 98.8% (96.5-100 [95-100]%) vs the open circuit improvement to 87.5%, (84.1-88.6 [82-89]%; p = 0.028). These data demonstrate the inverse relationship between supply and demand with open circuits and suggest that ambulatory closed circuits may offer twin advantages of supplying higher inspired oxygen concentrations and/or economy of gas use for exercising hypoxic adults.
-
Randomized Controlled Trial
Effect of positioning from supine and left lateral positions to left lateral tilt on maternal blood flow velocities and waveforms in full-term parturients.
Positioning the parturient from supine to the left lateral tilt position (supine-to-tilt) may not effectively displace the gravid uterus, but turning from the left lateral position to the left lateral tilt position (left lateral-to-tilt) may keep the gravid uterus displaced and prevent aortocaval compression. Fifty-one full-term parturients were randomly placed in the left lateral position, supine-to-tilt and left lateral-to-tilt positions using a Crawford wedge. ⋯ Our results showed a lower mean (SD) femoral vein area (82.2 (14.9) vs 96.2 (16.4) mm(2)), a lower pulsatility index (3.83 (1.3) vs 5.8 (2.2)), a lower resistance index (0.93 (0.06) vs 0.98 (0.57)), a higher femoral artery area (33.3 (3.8) vs 30.9 (4.4) mm(2)) and a higher femoral vein velocity (7.9 (1.2) vs 6.1 (1.6) cm.s(-1)) with left lateral-to-tilt when compared with supine-to-tilt (all p < 0.001). Our results suggest that moving a full-term parturient from the full left lateral to the lateral tilt position may prevent aortocaval compression in full-term parturients more efficiently than when positioning the parturient from a supine to left lateral tilt position.