Anaesthesia
-
We investigated whether the contamination of samples with glucose subsequently tested for haemostasis affected the results, including prothrombin time, activated partial thromboplastin time and fibrinogen concentration. Venous blood was collected from 12 healthy subjects and divided into four aliquots, which were subjected to different degrees of contamination with standard glucose solution (0%, 5%, 10%, 20%). With increasing glucose contamination, prothrombin time increased from mean (SD) 11.0 (0.7) s to 11.2 (0.7) s, 11.5 (0.7) s and 12.2 (0.8) s, all p < 0.001. ⋯ Fibrinogen concentration decreased from 3.8 (0.7) g.l(-1) to 3.7 (0.6) g.l(-1), 3.6 (0.6) g.l(-1), and 3.4 (0.6) g.l(-1), all p < 0.001. Bias was clinically meaningful from 5% contamination for activated partial thromboplastin time, 10% contamination for prothrombin time and 20% contamination for fibrinogen concentration. We conclude that if glucose contamination of haemostasis samples is suspected or has occurred, the specimens should not be analysed.
-
Review Meta Analysis Comparative Study
Comparison of streamlined liner of the pharynx airway (SLIPA(™) ) and laryngeal mask airway: a systematic review and meta-analysis.
We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during general anaesthesia. We included 14 studies with studies with 1273 patients in total. There was no evidence of a difference between the two devices in insertion success rate on the first attempt (13 studies, 1143 patients), insertion time (seven studies, 576 patients), ease of insertion (five studies, 466 patients), oropharyngeal leak pressure (eight studies, 771 patients) and the quality of the fibreoptic view of the larynx through the device (three studies, 281 patients). ⋯ Other adverse events were comparable. Subgroup analysis suggested that the insertion by novice users might be faster and more successful with the streamlined liner of the pharynx airway than the laryngeal mask airway; however, this was from only two studies and 186 patients. The method of size selection of the streamlined liner of the pharynx airway device might also affect the speed of insertion: choosing according to the width of the patient's thyroid cartilage, rather than height, may produce better results.
-
Randomized Controlled Trial Comparative Study
A randomised, single-blind technical study comparing the ultrasonic visibility of smooth-surfaced and textured needles in a soft embalmed cadaver model.
Visibility of the needle tip and shaft is important during ultrasound-guided regional anaesthesia in order to prevent nerve trauma. Tip and shaft visibility is reduced when needles are inserted in-plane at wide angles and out-of-plane at narrow angles to the ultrasound probe. Although textured needles are more reflective than smooth needles, we hypothesised that poor visibility of the tip and shaft still remained using the above angle-probe combinations. ⋯ The median (IQR [range]) proportions of visible needle tips were 83% (67-83 [50-100]%) for the textured Tuohy, 75% (67-83 [33-83]%) for the textured single-shot needle and 33% (33-46 [0-50]%) for the smooth-surfaced Tuohy (p = 0.0007). Median (IQR [range]) needle shaft visibility was rated as 4.0 (3.5-4.7 [3.0-4.9]) for the textured Tuohy, 4.0 (3.8-4.5 [2.7-4.9]) for the textured single-shot needle and 3.0 (2.4-3.3 [2.3-3.5]) for the smooth-surfaced Tuohy (p = 0.015). Nevertheless, visibility was reduced at wide angles in-plane and narrow angles out-of-plane both for needle tips (p = 0.004) and shafts (p = 0.005).