Der Anaesthesist
-
The neuromuscular and cardiovascular effects of vecuronium (Norcuron, Organon Teknika) were studied in 58 infants (1 day-10 months) and 65 children (1-6 years) anaesthetized either with halothane or under balanced anaesthesia. After a bolus dose of 70 micrograms/kg vecuronium the time course of neuromuscular blockade was determined using an electromyographic equipment. Onset time (time to maximal effect) was significantly shorter in infants compared with children; 1.4 +/- 0.7 min (min +/- SD) and 2.7 +/- 0.8 min, respectively. ⋯ Vecuronium (a bolus dose of 80 or 100 micrograms/kg) did not cause any significant change of blood pressure in infants and children anaesthetized either with halothane or by balanced anaesthesia. Infants under balanced anaesthesia showed a significant decrease in heart rate 15 min after administration of vecuronium. In contrast an increase in heart rate could be observed in children under halothane anesthesia, which was not attributed to vecuronium.
-
Randomized Controlled Trial Comparative Study Clinical Trial
[Etomidate versus methohexital for intravenous anesthesia with alfentanyl and nitrous oxide-oxygen. A double-blind study of circulatory behavior and postoperative course].
This study compared both etomidate and methohexitone for intravenous anaesthesia with alfentanil and nitrous oxide/oxygen in 2 X 20 patients scheduled for ENT-surgery, in a double blind, random fashion. Apart from the alternative use of etomidate and methohexitone the anaesthetic procedure did not differ: After a small dose of alfentanil anaesthesia was induced by a bolus dose of the hypnotic followed by a continuous infusion of the drug. In case of inadequate analgesia alfentanil was injected. ⋯ The dosage of etomidate and methohexitone was lowe than that reported in the literature. It proved to be impossible for the anaesthetist to decide which drug he was using. Hence both anaesthetic techniques compare favourably with each other.
-
Non-invasive measurements of oxygen saturation are attractive because they provide continuous information which may result in improved patient care. We evaluated a new finger pulse oximeter as a measure of arterial oxygen saturation in critically ill patients with respiratory distress. ⋯ Linear regression analysis of these pooled data yielded on excellent correlation (r = 0.97, p less than 0.001, 0.3% accuracy). The results demonstrate that non-invasive oxygen monitoring of patients with respiratory failure is feasible and can reliably detect potential life-threating arterial oxygen desaturation.