Der Anaesthesist
-
Randomized Controlled Trial Clinical Trial
[Repeated addition of fentanyl to bupivacaine peridural analgesia in labor. Clinical action and fentanyl plasma level].
A combination of epidural opioids with local anaesthetics has been used to improve pain relief during labor and to reduce side effects, such as muscle weakness, usually seen when local anaesthetics are used alone. The addition of epidural fentanyl (F) produces highly effective analgesia, the only side effect being mild itching. Initial trials investigated the improvement in analgesia after a single administration of F during first- but not during second-stage labor. ⋯ In one newborn, radioimmunoassay resulted in unexplainably high umbilical F concentrations without any clinical signs of sedation, depressed vigilance and without any sequellae. DISCUSSION. Repeated addition of 100 micrograms F to epidural anaesthesia with bupivacaine significantly improves analgesia and provides pain relief not only during the fir
-
Case Reports
[Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure].
Administration of highly concentrated, highly potent, and therefore highly dangerous drugs with syringe pumps is common in modern anaesthesia as well as in intensive care and emergency medicine. Because of their exact flow rates down to < 1 ml/h, these pumps are predestined for delivery of drugs with short half-lives, such as catecholamines and vasodilators. But intravenous application of drugs with syringe pumps is not without problems. ⋯ Even in a closed infusion system (syringe-extension-central venous catheter), hydrostatic pressure influences infusion rate. Elevation of the pump leads to unintended bolus administration, and lowering of the pump is followed by an interruption of the infusion. In the knowledge of this phenomenon, unexpected hemodynamic reactions during transport of critically ill patients cannot always be interpreted as a result of inadequate anesthesia or volume load, but may be a consequence of incorrect handling of the syringe pumps as described in this report.
-
Review
[The child with minor trauma. Does observation of fasting times reduce the risk of aspiration?].
According to a literature search, it seems most unlikely based on patho-physiological requirements and physiological aspects that traumatized children benefit from preoperative waiting times aimed at achieving a 6-h fast. Irrespective of fasting, traumatized children are at risk of requiring aspiration. Many generally recommended measures for the avoidance of aspiration are neither reasonable nor effective in traumatized children. The physical and psychological benefits that can be derived from shorter preoperative waiting times can more than over-ride the organizational difficulties caused by waiting longer.
-
Comparative Study Clinical Trial
[Venovenous extracorporeal membrane oxygenation (ECMO) with a heparin-lock bypass system. An effective addition in the treatment of acute respiratory failure (ARDS)].
Mortality of severe acute respiratory distress syndrome (ARDS) in Germany is about 60%. Respiratory therapy can make the lung injury worse by high positive airway pressures, high tidal volumes and high inspiratory oxygen concentrations. Extracorporeal membrane oxygenation (ECMO) was employed to reduce aggressive mechanical ventilation, but it has not been proved to be superior to conventional ventilation. ⋯ CONCLUSION. In comparison with the historical results at our own institution, the present study demonstrates an improvement in the survival rate from 56% to 78% since ECMO has become available. We conclude that venovenous ECMO with a heparin-bonded bypass circuit is an effective additional option for the treatment of patients with severe ARDS.
-
Comparative Study Clinical Trial
[Evaluation of the oscillometric blood pressure monitors: Dinamap 1846 and HP M-1008B].
Using the PTB simulator, which emits real signals from patients, we examined the precision of the oscillometric blood pressure measurement with the Dinamap 1846 (Critikon) and the HP M-1008B (Hewlett Packard). For this purpose we simultaneously registered invasive arterial pulsewave, cuff pressure and cuff pressure oscillations of 20 patients from our intensive care unit and stored them in the database of the simulator. The invasive reference blood pressure values were determined following the recommendations given by the Association for the Advancement of Medical Instrumentation. ⋯ The American Association for the Advancement of Medical Instrumentation recommends a maximum mean error of 5 +/- 8 mmHg. None of the examined instruments lay within these limits. Due to the systematic and stochastic errors, we think that the Dinamap 1846 (Critikon) and the HP M-1008B (Hewlett Packard) do not achieve performance levels that are adequate for measuring critically ill patients.