Der Anaesthesist
-
Randomized Controlled Trial Clinical Trial
[The interaction of nitrous oxide and enflurane on the EEG median of 2-3 Hz is additive, but weaker than at 1.0 MAC].
The aim of this study was to quantify the interaction of enflurane and nitrous oxide at a constant median EEG frequency. ⋯ The interaction of enflurane and nitrous oxide in the dose range from 0 to 75 vol.-% on median EEG frequency is compatible with additivity. The potency of nitrous oxide as a substitute for enflurane is less than might be expected when adding up the MAC values.
-
Randomized Controlled Trial Clinical Trial
[The effect of a heat and moisture exchanger (HME) on bronchial mucus transport in a closed inhalation anesthesia system].
The administration of dry anaesthetic gases for ventilation leads to morphological changes of the tracheobronchial epithelium that may cause postoperative pulmonary complications. Therefore, additional humidification with a heat and moisture exchanger (HME) is suggested for ventilation during anaesthesia, particularly when using semi-open breathing systems. Recommendations concerning the use of a HME in the semi-closed system are controversial. There are no data in the literature as to whether a HME improves mucociliary transport under these conditions. We therefore studied bronchial mucus transport velocity (BTV) with and without the use of a HME in the semi-closed circle system in humans. ⋯ BTV does not improve with the use of a HME in the semi-closed circle system with a fresh gas flow of 31. With modern anaesthesia machines lower fresh gas flows should be administered, whereby the humidity and temperature of the inspired gases are further increased.
-
Comparative Study
[Comparative study of the efficiency of bacterial filters in long-term mechanical ventilation].
Two commercially available bacterial filters to be used as part of the mechanical ventilation unit during anaesthesia were tested for hygienic criteria. Manufacturers claim that bacterial breathing filters have a filtration capacity of about 99.995%, so that there would be no need for thermal disinfection of tubing and ventilation circuits after each use. One filter is designed for a single use only, the other can be used up to 24 times after sterilisation. Both filters consist of hydrophobic glass fibres. ⋯ The use of bacterial filters during mechanical ventilation reduces the probability of bacterial contamination, but does not make sterilisation of the tubes and ventilation circuit unnecessary.
-
We describe unexpected episodes of paced tachycardia in two patients with rate-responsive pacemakers during anaesthesia. Five months after a heart transplant and implantation of a pacemaker a 43-year-old patient suffered cardiac tamponade as a result of chronic pericarditis. The second case involved embolic occlusion of the femoral artery in a 33-year-old female patient previously operated on for tricuspid valve replacement and implantation of a pacemaker. In both cases induction of anaesthesia was performed with fentanyl, etomidate and vecuronium. Following intubation and mechanical ventilation, the heart rates (HR) of the two patients increased to 140 and 130 min-1 respectively. This was interpreted as a sign of inadequate anaesthesia, and therefore additional doses of fentanyl and etomidate were given, with no effect on the tachycardia. After exclusion of other possible reasons for this complication such as hypokalaemia, hypercapnia, hypoxaemia or allergic reactions, unexpected functioning of the rate-responsive pacemakers due to thoracic impedance changes was assumed. Minute ventilation was reduced, lowering paced HR in 3-5 min. ⋯ These case reports suggest that anaesthetic management affects the action of rate-responsive pacemakers, causing haemodynamic complications, and inadequate interventions by the anaesthesiologist. Thus, it is necessary for anaesthesiologists to make a preoperative evaluation of the underlying medical disease and the type of pacemaker in order to adjust anaesthetic management accordingly and to understand the haemodynamic responses that may occur during the perioperative period. Preoperative programming to exclude the rate-responsive function is advised.