Gait & posture
-
This research evaluated whether quantified measures of trunk sway during clinical balance tasks are sensitive enough to identify a balance disorder and possibly specific enough to distinguish between different types of balance disorder. We used a light-weight, easy to attach, body-worn apparatus to measure trunk angular velocities in the roll and pitch planes during a number of stance and gait tasks similar to those of the Tinetti and CTSIB protocols. The tasks included standing on one or two legs both eyes-open and closed on a foam or firm support-surface, walking eight tandem steps, walking five steps while horizontally rotating or pitching the head, walking over low barriers, and up and down stairs. ⋯ Just over 50% of CPAT patients could be classified into a group with intermediate balance deficits, the rest were classified as normal. Our results indicate that measuring trunk sway in the form of roll angle and pitch angular velocity during five simple clinical tests of equilibrium, four of which probe both stance and gait control under more difficult sensory conditions, can reliably and quantitatively distinguish patients with a well defined balance deficit from healthy controls. Further, refinement of these trunk sway measuring techniques may be required if functions such as preliminary diagnosis rather than screening are to be attempted.