Improved detection of minor ischemic myocardial injury with measurement of serum cardiac troponin I.
This study compared the diagnostic accuracy of the measurement of serum cardiac troponin I (cTnI) with creatine kinase (CK) MB mass in patients with minor myocardial injury whose measured total CK activity did not exceed twice the upper reference limit (300 U/L for men; 200 U/L for women). Forty-eight consecutive patients presenting with chest pain and with in-hospital documentation of myocardial injury were enrolled. Electrocardiogram, echocardiogram, and serial serum CK-MB mass, cTnI, and total CK were measured over 36 h after admission. ⋯ The peak biochemical marker index (defined as CK-MB or cTnI divided by its respective upper reference limit) was significantly (P < 0.05) higher for cTnI than for CK-MB from 7 to 36 h. The clinical sensitivity for detection of myocardial injury for cTnI was 100% [95% confidence interval (CI): 87.2% to 100%], compared with 81.8% (CI: 67.3% to 91.8%) for CK-MB. Thus, cTnI was more sensitive than CK-MB mass for detection of myocardial injury in patients with small increases of total CK.