Osteoporotic/osteopenia fractures occur most frequently in trabeculae-rich skeletal sites. The purpose of this study was to use a high-resolution micro-computed tomography (micro-CT) and dual energy X-ray absorptionmeter (DEXA) to investigate the changes in micro-architecture and bone mineral density (BMD) in a sheep model resulted from ovariectomy (OVX). Biomechanical tests were performed to evaluate the strength of the trabecular bone. ⋯ In OVX sheep, changes in the structural parameters of trabecular bone are comparable to the human situation during osteoporosis was induced. The sheep model presented seems to meet the criteria for an osteopenia model for fracture treatment with respect to morphometric and mechanical properties. But the duration of OVX must be longer than 12 months to ensure the animal model can be established successfully.