Emergency radiology and mass casualty incidents-report of a mass casualty incident at a level 1 trauma center.
The aims of this article are to describe the events of a recent mass casualty incident (MCI) at our level 1 trauma center and to describe the radiology response to the event. We also describe the findings and recommendations of our radiology department after-action review. An MCI activation was triggered after an amphibious military vehicle, repurposed for tourist activities, carrying 37 passengers, collided with a charter bus carrying 45 passengers on a busy highway bridge in Seattle, WA, USA. ⋯ The mean number of radiographic studies performed per patient was 3 (range 1-8), and the total number of injuries detected was 88. The surge in imaging requirements during an MCI can be significant and exceed normal operating capacity. This report of our radiology experience during a recent MCI and subsequent after-action review serves to provide an example of how radiology capacity and workflow functioned during an MCI, in order to provide emergency radiologists and response planners with practical recommendations for implementation in the event of a future MCI.
-
Emergency radiology · Feb 2017
CT of suspected thoracic acute aortic injury in the emergency department: is routine abdominopelvic imaging worth the additional collective radiation dose?
This study aimed to determine the incidence of non-traumatic acute aortic injury (AAI) extending from the chest into the abdomen or pelvis in emergency department (ED) patients with acute aortic syndrome (AAS), to estimate the effective dose of the abdominopelvic portion of these CT exams, and to compare the number needed to screen (NNS) with the collective population radiation dose of imaging those stations. All patients (n = 238) presenting to the ED with AAS between March 2014 and June 2015 who were imaged per CT AAI protocol (noncontrast and contrast-enhanced CT angiography of the chest, abdomen, and pelvis) were retrospectively identified in this IRB-approved HIPAA-compliant study. The Stanford classification for positive cases of AAI was further subclassified based on chest, abdominal, or pelvic involvement. ⋯ The collective effective doses to the abdomen and pelvis with unenhanced CT and CTA in 59.5 patients and 238 patients were 761.6 and 3046.4 mSv, respectively. While the estimated mean effective dose for imaging of the abdominopelvic stations are low, the collective effective dose should also be considered. It may be beneficial to modify or omit routine unenhanced CT and/or CTA of the abdomen/pelvis in this patient population in the absence of abdominal symptoms, and image the abdomen and pelvis in positive thoracic cases only.
-
Emergency radiology · Feb 2017
Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?
The objective of this study was the assessment of the image quality and radiation dose in polytrauma CT using immobilization devices. An anthropomorphic whole body and a liver phantom were scanned on a 128-slice CT scanner with four different protocols using automatic tube current modulation (120 kVp, 150 ref. mAs; 120 kV, 200 ref. mAs; 140 kVp, 150 ref. mAs; and 140 kVp, 200 ref. mAs) and four different setups (no immobilization device (setup A), vacuum mattress 1 (setup B), vacuum mattress 2 (setup C), and spineboard (setup D)). Qualitative and quantitative image quality parameters and radiation dose were assessed. ⋯ Severe streak artifacts, provoked by the inflation valve of the mattresses were detected at the level of the head and shoulder. Applying immobilization devices for whole-body CT with automatic tube current modulation increases the radiation dose and decreases the quantitative image quality slightly. Severe artifacts, induced by the inflation valve of the mattress, can influence the diagnostic accuracy at the level of the head and shoulder.