The American journal of orthopedics
-
The use of a very proximal insertion site for rigid intramedullary nailing was evaluated in a biomechanical study. The purpose of this study was to compare the bursting strains generated in a proximal tibia fracture fragment during rigid nailing, using the recommended insertion sites versus a more proximal site just anterior to the tibial plateau in the midline. Proximal one-third tibia fractures were created in 12 pairs of fresh cadaver specimens. ⋯ In the Lottes group, much larger bursting strains were generated in the lateral cortex when using a distal starting point (P < 0.05). In the unreamed Russell-Taylor group, the anteromedial surface strains were significantly increased using a distal starting point (P < 0.05). The Grosse-Kempf group showed no significant difference in strains associated with any insertion point during tibial intramedullary nailing.