Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.]
-
Comparative Study Clinical Trial
An in vivo trial comparing the clinical efficacy and complications of Q-switched 755 nm alexandrite and Q-switched 1064 nm Nd:YAG lasers in the treatment of nevus of Ota.
Q-switched 755 nm alexandrite (QS alex) and Q-switched 1064 nm Nd:YAG lasers are effective in the treatment of nevus of Ota. Our previous in vivo study indicated that patients better tolerate QS alex than QS 1064 nm Nd:YAG laser. However, in terms of clinical efficacy and long-term complications, the study did not indicate which laser is superior. Although both machines may appear to be similar in effectiveness, the low number of treatment sessions may contribute to this apparent lack of difference. ⋯ QS 1064 nm Nd:YAG laser appears to be more effective than QS alex in the lightening of nevus of Ota after three or more laser treatment sessions. However, the majority (55%) of the patients reported no differences in results between the two lasers, and only one of the two observers noted statistically significant improvement of QS 1064 nm Nd:YAG over QS alex.