Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.]
-
Pediatric patients undergoing surgical procedures may experience considerable anxiety. Use of conscious sedation may be helpful in managing mild to moderate anxiety. ⋯ Monitored use of a combination of oral benzodiazepine and low to moderate concentrations of inhaled nitrous oxide can provide safe and effective conscious sedation in pediatric patients. Training in conscious sedation and emergency preparedness are essential.
-
Comparative Study
When one liter does not equal 1000 milliliters: implications for the tumescent technique.
Tumescent anesthesia has revolutionized the practice of liposuction. Inherent to the tumescent technique is the use of large volumes of dilute solutions of lidocaine with epinephrine instilled into subcutaneous fat deposits. Precise formulation of the tumescent anesthesia is essential to liposuction technique. ⋯ One liter IV bags of normal saline contain more than 1 L, having an average volume of 1051 ml. Common methods of preparation of 0.05% lidocaine with 1:1,000,000 epinephrine and sodium bicarbonate can increase the total amount of fluid in the tumescent anesthesia to 1112 ml for 0.05% solutions and preparation of a 0.1% solution contains an average volume of 1162 ml. The fluid contained in each bag may be increased over labeling by as much as 11-16%. Final concentrations of lidocaine in tumescent anesthesia may be reduced due to extra fluids. A 0.05% lidocaine solution may have a final lidocaine concentration of 0.045% and a 0.1% lidocaine solution may have an actual concentration of 0.086%. Lidocaine concentrations may be reduced by as much as 10-14%. Extra anesthesia fluid is also contained within stock 50 ml bottles of 1% lidocaine. Dermatologic surgeons should be aware of extra fluid possibly contained within tumescent anesthetic preparation, be aware of the extra anesthesia supplied in standard 1% lidocaine bottles, and possible decreased concentration of lidocaine within the final tumescent anesthesia.
-
Comparative Study Clinical Trial
An in vivo trial comparing the clinical efficacy and complications of Q-switched 755 nm alexandrite and Q-switched 1064 nm Nd:YAG lasers in the treatment of nevus of Ota.
Q-switched 755 nm alexandrite (QS alex) and Q-switched 1064 nm Nd:YAG lasers are effective in the treatment of nevus of Ota. Our previous in vivo study indicated that patients better tolerate QS alex than QS 1064 nm Nd:YAG laser. However, in terms of clinical efficacy and long-term complications, the study did not indicate which laser is superior. Although both machines may appear to be similar in effectiveness, the low number of treatment sessions may contribute to this apparent lack of difference. ⋯ QS 1064 nm Nd:YAG laser appears to be more effective than QS alex in the lightening of nevus of Ota after three or more laser treatment sessions. However, the majority (55%) of the patients reported no differences in results between the two lasers, and only one of the two observers noted statistically significant improvement of QS 1064 nm Nd:YAG over QS alex.