European journal of oral sciences
-
Randomized Controlled Trial
Assessment of sleep parameters during contingent electrical stimulation in subjects with jaw muscle activity during sleep: a polysomnographic study.
There is emerging evidence that feedback techniques based on contingent electrical stimulation (CES) have an inhibitory effect on the electromyogram (EMG) activity of jaw-closing muscles and therefore could be useful in the management of sleep bruxism. This polysomnographic (PSG) study was designed to investigate the effect of CES on PSG parameters in subjects with self-reported bruxism. Fourteen subjects underwent a full PSG investigation in the laboratory for three consecutive nights - one night of adaptation, one night without CES, and one night with CES - in a randomized order. ⋯ The total sleep time, the number of micro-arousals per hour of sleep, the time spent in sleep stages 3 and 4 and in rapid eye movement (REM) sleep, and the number of periodic limb movements, were not influenced by CES. The number of EMG episodes per hour of sleep during the nights with and without CES was not significantly different. The present study suggests that CES at non-painful intensities does not cause major arousal responses in any of the sleep parameters assessed in this study.
-
Comparative Study
Biological and physicochemical properties of carbon-graphite fibre-reinforced polymers intended for implant suprastructures.
The aim of this study was to determine water sorption, water solubility, dimensional change caused by water storage, residual monomers, and possible cytotoxic effects of heat-polymerized carbon-graphite fibre-reinforced composites with different fibre loadings based on methyl methacrylate/poly(methyl methacrylate) (MMA/PMMA) and the copolymer poly (vinyl chloride-co-vinyl acetate). Two different resin systems were used. Resin A contained ethylene glycol dimethacrylate (EGDMA) and 1,4-butanediol dimethacrylate (1,4-BDMA); the cross-linker in Resin B was diethylene glycol dimethacrylate (DEGDMA). ⋯ For all composites, the volumetric increase was below 0.01±0.005 vol%. Residual MMA monomer was equal to or below 0.68±0.05 wt% for the fibre composites. The filter diffusion test and the (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) (MTT) assay demonstrated no cytotoxicity for the carbon-graphite fibre-reinforced composites, and residual cross-linking agents and vinyl chloride were not detectable by high-performance liquid chromatography (HPLC) analysis.