Journal of telemedicine and telecare
-
Introduction Intensivist involvement for patients with sepsis is associated with decreased complications and mortality, and lower hospital resource utilization, but few studies have evaluated outcomes for patients exposed to electronic intensive care unit (eICU) telemedicine sepsis management in the emergency department (ED). In this study, we assess whether eICU cart exposure in the ED improved compliance with components of the 2010 Surviving Sepsis Campaign bundles, length of stay (LOS), disposition and hospital costs. Methods An institutional review board-approved, retrospective cohort study was completed on patients with confirmed sepsis who presented to our ED from July 2010 through February 2013. ⋯ Total hospital costs for the exposed cohort were lower and less variable (US$19,713 ± 16,550 vs. US$24,364 ± 25068), but this was not significant ( p = 0.274). Discussion Our findings suggest that in individuals with confirmed sepsis, ED exposure to a telemedicine-based eICU cart impacted adherence to aspects of the Surviving Sepsis Campaign recommended bundle, but did not impact overall survival and medical costs.