Investigative radiology
-
Investigative radiology · Dec 2007
Comparative StudyValue of diffusion-weighted imaging for the prediction of prostate cancer location at 3T using a phased-array coil: preliminary results.
To retrospectively evaluate the imaging quality of diffusion-weighted imaging (DWI), compare the apparent diffusion coefficient (ADC) values for malignant and benign tissues in the peripheral zone (PZ) and transition zone (TZ), and evaluate whether T2-weighted imaging (T2WI) with DWI could improve the prediction of prostate cancer location when compared with T2WI at 3T using a phased-array coil. ⋯ DWI is a feasible technique that can be used for the differentiation of malignant and benign tissues in the PZ and TZ. Additionally, T2WI with DWI is superior to T2WI alone for the prediction of prostate cancer location.