Respirology : official journal of the Asian Pacific Society of Respirology
-
Multicenter Study Observational Study
Accuracy of PaO2 /FiO2 calculated from SpO2 for severity assessment in ED patients with pneumonia.
Assessment of oxygenation in patients with community-acquired pneumonia is critical for treatment. The accuracy of percutaneous oxygen saturation (SpO2 ) determined by pulse oximetry is uncertain, and it has limited value in patients receiving supplemental oxygen. We hypothesized that calculation of partial arterial oxygen concentration/inspired oxygen faction (PaO2 /FiO2 ) from SpO2 by the Ellis or Rice equations might adequately correlate with PaO2 /FiO2 measured by arterial blood gases. ⋯ The Ellis equation was more accurate than the Rice equation for estimating PaO2 /FiO2 , especially at higher levels of P/F ratio. Estimation of PaO2 /FiO2 from SpO2 is accurate enough for initial oxygenation assessment. Ellis and Rice equations could misclassify 20% and 30% of patients, respectively, at higher levels of PaO2 /FiO2 . For patients with abnormal oxygenation falling near thresholds for clinical decision making, arterial blood gas measurement preferably on room air is more accurate.