British journal of anaesthesia
-
Comparative Study
Does manual anaesthetic record capture remove clinically important data?
Numerous studies have shown smoothing and inaccuracies in handwritten anaesthetic records, but the clinical relevance of these findings is unclear. We therefore sought to determine whether the behaviour of anaesthetists differed in assessing anaesthetic records re-synthesized from either handwritten or automated records. ⋯ In comparison with computerized record-keeping, manual record-keeping resulted in loss of clinically relevant information.
-
Cardiac output (CO) monitoring by uncalibrated arterial pressure waveform analysis (APCO) using the FloTrac/Vigileo™ is feasible in patients with intracranial haemorrhage, but the results of validation studies are contradictory. The aim of the present study was to analyse the clinical agreement between the intermittent bolus thermodilution technique (TDCO) and APCO in patients with non-traumatic intracranial haemorrhage. ⋯ The second generation of FloTrac(®)/Vigileo(®) monitoring system underestimates the TDCO in patients with non-traumatic intracranial haemorrhage. The bias correlates with measured systemic vascular resistance. The upper calibration level does not affect the results.
-
The current prevalence of healthcare-associated infections (HCAIs) is a major public health concern. Patient contact in the operating theatre (OT) can contribute to HCAI via microbial contamination. The application of hand hygiene is effective in reducing infection rates. Limited data are available on adherence to hand-hygiene guidelines by OT staff. ⋯ Frequent interactions between patient, staff, and OT environment were observed. Adherence to hand-hygiene guidelines by OT staff was extremely low. This potentially exposes patients to microbial transmission, HCAIs, and patient harm.
-
Pulse pressure variation (PPV) and systolic pressure variation (SPV) are reliable predictors of fluid responsiveness in patients undergoing controlled mechanical ventilation. Currently, PPV and SPV are measured invasively and it is unknown if an arterial pressure (AP) signal obtained with a finger cuff can be used as an alternative. The aim of this study was to validate PPV and SPV measured using a finger cuff. ⋯ In patients receiving controlled mechanical ventilation after CABG, PPV and SPV can be measured reliably non-invasively using the inflatable finger cuff of the Nexfin™ monitor.
-
Desflurane triggers post-conditioning in the diabetic human myocardium. We determined whether protein kinase C (PKC), mitochondrial adenosine triphosphate-sensitive potassium (mitoK(ATP)) channels, Akt, and glycogen synthase kinase-3β (GSK-3β) were involved in the in vitro desflurane-induced post-conditioning of human myocardium from patients with type 2 diabetes. ⋯ Desflurane-induced post-conditioning in human myocardium from patients with type 2 diabetes was mediated by the activation of PKC, the opening of the mitoK(ATP) channels, and the phosphorylation of Akt and GSK-3β.