Computer methods in biomechanics and biomedical engineering
-
Comput Methods Biomech Biomed Engin · Jan 2013
Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk.
Currently, mechanical support is the most promising alternative to cardiac transplantation. Ventricular assist devices (VADs) were originally used to provide mechanical circulatory support in patients awaiting planned heart transplantation ('bridge-to-transplantation' therapy). The success of short-term bridge devices led to clinical trials evaluating the clinical suitability of long-term support ('destination' therapy) with left ventricular assist devices (LVADs). The first larger scale, randomised trial that tested long-term support with an LVAD reported a 44% reduction in the risk of stroke or death in patients with an LVAD. In spite of the success of LVADs as bridge-to-transplantation and long-term support, patients managed by these devices are still at risk of several adverse events. The most devastating complication is caused by embolisation of thrombi formed within the LVAD or inside the heart into the brain. Prevention of thrombi formation is attempted through anticoagulation management and by improving LVADs design; however, there is still significant occurrence of thromboembolic events in patients. Investigators have reported that the incidence of thromboembolic cerebral events ranges from 14% to 47% over a period of 6-12 months. ⋯ The adjustment of the location of the anastomosis of the LVAD outflow cannula as well as its angle of incidence plays a significant role in the level of thromboembolisms. By proper adjustment in this CFD study of a synthetic model of an aortic arch bed, we found that nearly a 50% reduction in cerebral embolism could be achieved for a configuration consisting of a shallow angle of implantation over a baseline normal incidence of the LVAD cannula. Within the limitations of our model, we have established that the LVAD implantation geometry is an important factor and should be taken into consideration when implanting an LVAD. It is possible that other parameters such as distance of the LVAD outflow cannula to the root of the IA could affect the thrombi embolisation probabilities. However, the results of this study suggest that the risk of stroke may be significantly reduced by as much as 50% by tailoring the VAD implantation by a simple surgical manoeuvre. The results of this line of research may ultimately lead to techniques that can be used to estimate the optimal LVAD configuration in a patient-specific manner by pre-operative imaging.
-
Comput Methods Biomech Biomed Engin · Jan 2013
How does muscle stiffness affect the internal deformations within the soft tissue layers of the buttocks under constant loading?
Mechanical loading of soft tissues covering bony prominences can cause skeletal muscle damage, ultimately resulting in a severe pressure ulcer termed deep tissue injury (DTI). Deformation plays an important role in the aetiology of DTI. Therefore, it is essential to minimise internal muscle deformations in subjects at risk of DTI. ⋯ For example, a change in muscle stiffness had a large effect on the muscle deformations. A 50% decrease in stiffness caused an increase in maximum shear strain from 0.65 to 0.99, whereas a 50% increase in stiffness resulted in a decrease in maximum shear strain from 0.65 to 0.49. These results indicate the importance of restoring tissue properties after SCI, with the use of, for example, electrical stimulation, to prevent the development of DTI.