Computer methods in biomechanics and biomedical engineering
-
Comput Methods Biomech Biomed Engin · Apr 2017
On the assessment of bridging vein rupture associated acute subdural hematoma through finite element analysis.
Acute subdural hematoma (ASDH) is a type of intracranial haemorrhage following head impact, with high mortality rates. Bridging vein (BV) rupture is a major cause of ASDH, which is why a biofidelic representation of BVs in finite element (FE) head models is essential for the successful prediction of ASDH. We investigated the mechanical behavior of BVs in the KTH FE head model. ⋯ The success rate fluctuated between 67 and 75%. To further increase the predictive capability of FE head models w.r.t. BV rupture, future work should be directed towards improvement of the BV representation, both geometrically and mechanically.
-
Comput Methods Biomech Biomed Engin · Apr 2017
Loading of the lumbar spine during backpack carriage.
Backpack carriage is significantly associated with a higher prevalence of low back pain. Elevated compression and shear forces in the lumbar intervertebral discs are known risk factors. ⋯ The results revealed that to predict realistic lumbar compression forces, subject-specific lumbar curvature data were not necessary for loads up to 40 kg. In contrast, regarding shear forces, using subject-specific lumbar curvature data from upright MRI measurements as input for the rigid body model significantly altered lumbar joint force estimates.
-
Comput Methods Biomech Biomed Engin · Apr 2017
Sensitivity of lumbar spine response to follower load and flexion moment: finite element study.
The follower load (FL) combined with moments is commonly used to approximate flexed/extended posture of the lumbar spine in absence of muscles in biomechanical studies. There is a lack of consensus as to what magnitudes simulate better the physiological conditions. Considering the in-vivo measured values of the intradiscal pressure (IDP), intervertebral rotations (IVRs) and the disc loads, sensitivity of these spinal responses to different FL and flexion moment magnitudes was investigated using a 3D nonlinear finite element (FE) model of ligamentous lumbosacral spine. ⋯ The FL magnitude had reverse effect on the IDP and disc force. Thus, magnitude for FL or flexion that minimizes the deviation of all the spinal parameters together from the in-vivo data can vary. To obtain reasonable compromise between the IDP and disc force, our findings recommend that FL of low magnitude must be combined with flexion moment of high intensity and vice versa.